Blood culture: Difference between revisions

Kbrunton (talk | contribs)
m eliminated discrepancy from lab list article and this article in regards to what is a SET for blood draw
GHall (talk | contribs)
Line 2: Line 2:


== Protocol ==
== Protocol ==
For the purpose of the ICU lab count collection we are counting the number of''' sites''' and '''not sets'''. Our guidelines for counting blood cultures have nothing to do with any other guidelines or criteria.
For example:
Blood drawn from one site inoculated into any number of bottles=1
Blood drawn from two sites inoculated into any number of bottles=2
This was discussed and decided by Dr Garland at the task meeting on August 21,2014
Tina will move this discussion below.
A blood culture is a microbiological "procedure" that is ordered as a '''set.'''   
A blood culture is a microbiological "procedure" that is ordered as a '''set.'''   


Line 15: Line 25:
* 2 bottles from 1 venipuncture site, this is not a complete blood culture and the question is "why would a unit not be following a protocol"?
* 2 bottles from 1 venipuncture site, this is not a complete blood culture and the question is "why would a unit not be following a protocol"?
** This should only be counted as ONE SET of blood cultures.
** This should only be counted as ONE SET of blood cultures.
***  1 aerobic and 1 anaerobic bottle from 1 site = 1 count//// 2aerobic and 2 anaerobic bottles =4 bottles from 2 different site = 2 count Is this not correct? We spoke with micro here at the Vic when getting blood cultures from a peripheral poke you draw one aerobic and one anaerobic bottle and because it is peripheral ,the lab wants a control sample( to rule out if it is a contaminent) from a second  peripheral site doesnt need to be a new poke can be from old lok.>24 hours) which = 1 count  
***  1 aerobic and 1 anaerobic bottle from 1 site = 1 count//// 2aerobic and 2 anaerobic bottles =4 bottles from 2 different site = 2 count Is this not correct? We spoke with micro here at the Vic when getting blood cultures from a peripheral poke you draw one aerobic and one anaerobic bottle and because it is peripheral ,the lab wants a control sample( to rule out if it is a contaminent) from a second  peripheral site doesnt need to be a new poke can be from old lok.>24 hours) which = 1 count
 
==article related to==
==article related to==
*[[Central Line Related Blood stream Infection (CLR-BSI)]]
*[[Central Line Related Blood stream Infection (CLR-BSI)]]