TISS Cardiovascular

TISS therapeutic variables: T9 to T25

  • 9 - ECG monitoring
  • 10 - Hourly Vital signs -Minimum 6 hrs consecutively in the first 24 hrs in ICU to get points
  • 11 - Peripheral arterial line
  • 12 - Pulmonary arterial line
  • 13 - Measurement of CVP (any method)
  • 14 - Measurement of Cardiac Output
  • 15 - Temporary Pacemaker-Standby (includes external) - wires hooked up but pace not turned on.
  • 16 - Temporary Pacemaker-Active (includes external) - turned on but may not be pacing all the time.
    • The testing for "capture" not counted as active pacing.
    • Permanent pacer not included.
  • 17 - Post Cardiac Arrest - (first 48 hours) mark for 2 days
  • 18 - Cardioversion/Defibrillation - While in ICU only
  • 19 - IABP
    • NOTE: Community hospitals (Oaks, Grace, Concordia, Victoria). If a patient goes from your center to STB or HSC for an angiogram/plasty, has an IABP inserted in the angio department and is either admitted for HSC or STB ICU/CCU or goes directly to the OR from there, please do not put on your TISS item # 19 -IABP.Discharge to should be coded using the codes for HSC or STB for OR , CCU , SICU or MICU.