Query check CCI InExtubation consistent: Difference between revisions
Jump to navigation
Jump to search
Ttenbergen (talk | contribs) mNo edit summary |
No edit summary |
||
Line 20: | Line 20: | ||
*** What I was trying to say is that I am worried this would be a false positive, which will then create work load for Pagasa and/or Collectors to confirm. Do we really want cross checks that bring up ''potential'' errors? We have talked about this before, but never really come up with a general answer. Should we take it to task meeting? Ttenbergen 23:45, 2018 October 29 (CDT) | *** What I was trying to say is that I am worried this would be a false positive, which will then create work load for Pagasa and/or Collectors to confirm. Do we really want cross checks that bring up ''potential'' errors? We have talked about this before, but never really come up with a general answer. Should we take it to task meeting? Ttenbergen 23:45, 2018 October 29 (CDT) | ||
*** Are you saying I should use "difference between A and B can be -2, -1, 0, 1, 2. Other values will be questionable? | *** Are you saying I should use "difference between A and B can be -2, -1, 0, 1, 2. Other values will be questionable? | ||
**** The basic scenarios are 1. no new insert and no extubation (0-0=0) , 2. no new insert and then extubated - this assumes currently with tube and then extubated (0-1=-1), 3. insert new tube and no extubation(1-0=1), 4) insert new tube and then extubated (1-1=0). When there are 2 insertions, the valid number of extubations =1,2,3 even if occurring at same or different days as insertion day, the difference will either be -1,0,1. Same holds true with 3 insertions or 4 insertions. there will be definite errors if the difference is >= 2 or <= -2. Having 1 insertion and 3 extubations or 3 insertions and 1 extubation are not possible and are errors. | |||
}} | }} | ||
== Related articles == | == Related articles == | ||
{{Related Articles}} | {{Related Articles}} |
Revision as of 15:47, 2018 November 15
Data Integrity Checks | |
Summary: | Any marked TISS Item Insertion of ETT (TISS Item) or in ETT Present (TISS Item) must have at least one marked TISS item either in Planned extubation (TISS Item) or in Unplanned extubation (TISS Item) |
Related: | Insertion of ETT (TISS Item), Planned extubation (TISS Item), Unplanned extubation (TISS Item) |
Firmness: | hard check |
Timing: | always |
App: | Centralized data front end.accdb |
Coding: | |
Uses L Problem table: | not entered |
Status: | needs review |
Implementation Date: | 2018-10-25 |
Backlogged: | true |
Any marked TISS Item Insertion of ETT (TISS Item) or in ETT Present (TISS Item) must have at least one marked TISS item either in Planned extubation (TISS Item) or in Unplanned extubation (TISS Item)
Query1 - Insertion of ETT and Extubation consistency
- A = Total the number of days Insertion of ETT (TISS Item) are marked per patient
- B = Total the number of days Planned extubation (TISS Item) and Unplanned extubation (TISS Item) are marked per patient
- The difference between A and B can be -1, 0, 1. Other values will be questionable.
|
Related articles
Related articles: |