Query check CCI InExtubation consistent: Difference between revisions

From CCMDB Wiki
Jump to navigation Jump to search
m (Text replacement - "Discuss | who = Tina" to "TT")
Line 15: Line 15:
* The difference between A and B can be -1, 0, 1.  Other values will be questionable.
* The difference between A and B can be -1, 0, 1.  Other values will be questionable.


{{Discuss | who = Tina | question =_Dev_CFE
{{TT | question =_Dev_CFE
* this cross check would not know the difference between (on one day, intubated, extubated, and reintubated) vs (intubated and then extubated); while this hopefully not too common of a thing, would it cause false positives for Pagasa to run after? Ttenbergen 11:33, 2018 October 29 (CDT)  
* this cross check would not know the difference between (on one day, intubated, extubated, and reintubated) vs (intubated and then extubated); while this hopefully not too common of a thing, would it cause false positives for Pagasa to run after? Ttenbergen 11:33, 2018 October 29 (CDT)  
**yes that is correct because both have a difference of zero. Using the cut off GTE Abs(2) will get true negatives and not false positives.  This query considers only the counts and not the dates which will have numerous scenarios and too complicated to define. For those having a difference of -1,0,1 , there are also the possibility for incorrect sequence of dates of intubation or extubation  - this is not captured in the query.  If you have other suggestions, let us know.--[[User:JMojica|JMojica]] 12:19, 2018 October 29 (CDT)
**yes that is correct because both have a difference of zero. Using the cut off GTE Abs(2) will get true negatives and not false positives.  This query considers only the counts and not the dates which will have numerous scenarios and too complicated to define. For those having a difference of -1,0,1 , there are also the possibility for incorrect sequence of dates of intubation or extubation  - this is not captured in the query.  If you have other suggestions, let us know.--[[User:JMojica|JMojica]] 12:19, 2018 October 29 (CDT)

Revision as of 17:07, 2020 May 5

Data Integrity Checks
Summary: Any marked TISS Item T40 - Insertion of ETT (TISS Item) or in T22 - ETT Present (TISS Item) must have at least one marked TISS item either in T28 - Planned extubation (TISS Item) or in T29 - Unplanned extubation (TISS Item)
Related: Insertion of ETT (TISS Item), Planned extubation (TISS Item), Unplanned extubation (TISS Item)
Firmness: hard check
Timing: always
App: Centralized data front end.accdb
Coding:
Uses L Problem table: not entered
Status: ready to implement
Implementation Date: 2018-10-25
Backlogged: true
  • Cargo


  • SMW


  • Categories: 
  • form:

Any marked TISS Item T40 - Insertion of ETT (TISS Item) or in T22 - ETT Present (TISS Item) must have at least one marked TISS item either in T28 - Planned extubation (TISS Item) or in T29 - Unplanned extubation (TISS Item)

Query1 - Insertion of ETT and Extubation consistency


{{{1}}}

  • added: no added date
  • action: no action date
  • Cargo


  • Categories

Related articles

Related articles: