Data Integrity Checks
|
Summary:
|
The D_ID on a TISS28 form does not exist in CFE
|
Related:
|
CFE, D_ID
|
Firmness:
|
hard check
|
Timing:
|
always
|
App:
|
TISS28.accdb
|
Coding:
|
query TISS_Errors_D_ID_not_in_CFE
|
Uses L Problem table:
|
not relevant for this app
|
Status:
|
retired
|
Implementation Date:
|
not entered
|
Backlogged:
|
true
|
No longer relevant now that TISS info is entered directly and stored in CCI
Causes and solutions
- look up the PHIN number on the scanned form image
- go to CFE, look up the patient with that PHIN and use the Cat button to find related records
- check if the to and from fields tell you that this was a wrong location, confirm via Finding a patient in EPR what the location should be
- check the serial number part of D_ID to see if one is similar to the one on the TISS form; if so, follow Fixing a D ID in TISS28.accdb and change the TISS D_ID to the one from CFE
Log
- 2019-02-11 - changed to ckeck last 90 days now that Pagasa has explained that TISS collection might be far behind.