Query TISS Errors NrTISSDays NE LOS: Difference between revisions

From CCMDB Wiki
Jump to navigation Jump to search
mNo edit summary
mNo edit summary
 
Line 5: Line 5:
{{Data Integrity Check
{{Data Integrity Check
|DIC_summary=Length of stay ([[LOS]]) for all ICU patients must be consistent with their number of TISS days, incl no TISS days at all (ie missing forms).
|DIC_summary=Length of stay ([[LOS]]) for all ICU patients must be consistent with their number of TISS days, incl no TISS days at all (ie missing forms).
|DIC_related_concepts=LOS; TISS; Arrive DtTm field; Dispo DtTm field
|DIC_related_concepts=LOS; TISS; Dispo DtTm field
|DIC_firmness=hard check
|DIC_firmness=hard check
|DIC_coding=query ''TISS_Errors_NrTISSDays_NE_LOS''
|DIC_coding=query ''TISS_Errors_NrTISSDays_NE_LOS''
Line 12: Line 12:
|DIC_app=CCMDB.accdb
|DIC_app=CCMDB.accdb
}}
}}
.
 
See [[Query check CCI TISS NrDays LT LOS]] and [[Query check CCI TISS NrDays GT LOS]] instead.
See [[Query check CCI TISS NrDays LT LOS]] and [[Query check CCI TISS NrDays GT LOS]] instead.



Latest revision as of 16:32, 2022 April 14

Legacy Content

This page contains Legacy Content.

Click Expand to show legacy content.

Data Integrity Checks
Summary: Length of stay (LOS) for all ICU patients must be consistent with their number of TISS days, incl no TISS days at all (ie missing forms).
Related: LOS, TISS, Dispo DtTm field
Firmness: hard check
Timing: always
App: CCMDB.accdb
Coding: query TISS_Errors_NrTISSDays_NE_LOS
Uses L Problem table: not relevant for this app
Status: declined
Implementation Date: 2016-07-11
Backlogged: true
  • Cargo


  • SMW


  • Categories: 
  • form:

See Query check CCI TISS NrDays LT LOS and Query check CCI TISS NrDays GT LOS instead.

Causes and solutions

  • if LOS lower than TISS_Day_Count, there likely is a missing TISS form, likely; this would probably have shown up and been questioned for Query TISS Errors missing days.
  • if LOS higher than TISS_Day_Count
    • the problem might be
      • form may not have arrived and been scanned yet (e.g. consider if collector is away, forms may just not be here yet)
      • form may have been scanned with wrong serial or unit (either form wrong, or not wrong in verifier)
    • review images of TISS forms
      • copy D_ID
      • open "lookup image" form and paste into and click image button
    • review dates in EPR, possibly

Log

Related articles