Query check CCI InExtubation consistent: Difference between revisions

From CCMDB Wiki
Jump to navigation Jump to search
mNo edit summary
Line 25: Line 25:
This will be implemented as a soft check because, due to the fact we only allow one entry per day for the CCIs, there are scenarios in which the difference would be more than 1.  
This will be implemented as a soft check because, due to the fact we only allow one entry per day for the CCIs, there are scenarios in which the difference would be more than 1.  


Example:  
Examples:  
Pt arrives intubated. On day 1, they are extubated. On day 2 they are intubated, extubated and then intubated again on the same day, which will look on TISS as one insertion on that day and one removal. If you then had a removal the next day you will have an error because you have a count of 3 extubations with only 1 intubation.
* Pt arrives intubated. On day 1, they are extubated. On day 2 they are intubated, extubated and then intubated again on the same day, which will look on TISS as one insertion on that day and one removal. If you then had a removal the next day you will have an error because you have a count of 3 extubations with only 1 intubation.
* We don’t always extubate for those that are ill and have cardiac arrest and die, we often leave the ETT in


== Related articles ==
== Related articles ==
{{Related Articles}}
{{Related Articles}}

Revision as of 15:08, 2021 July 15

Data Integrity Checks
Summary: Any marked TISS Item T40 - Insertion of ETT (TISS Item) or in T22 - ETT Present (TISS Item) must have at least one marked TISS item either in T28 - Planned extubation (TISS Item) or in T29 - Unplanned extubation (TISS Item)
Related: Insertion of ETT (TISS Item), Planned extubation (TISS Item), Unplanned extubation (TISS Item)
Firmness: soft check
Timing: always
App: CCMDB.accdb
Coding:
Uses L Problem table: not relevant for this app
Status: ready to implement
Implementation Date:
Backlogged: true
  • Cargo


  • SMW


  • Categories: 
  • form:

_Dev_CCMDB

  • This could be done in CCMDB instead now that we collect TISS there. Confirming with Lisa if she thinks this would be problematic.
  • added: 2021-07-15
  • action: 2021-07-22
  • Cargo


  • Categories

Insertion of ETT and Extubation consistency

Soft check

This will be implemented as a soft check because, due to the fact we only allow one entry per day for the CCIs, there are scenarios in which the difference would be more than 1.

Examples:

  • Pt arrives intubated. On day 1, they are extubated. On day 2 they are intubated, extubated and then intubated again on the same day, which will look on TISS as one insertion on that day and one removal. If you then had a removal the next day you will have an error because you have a count of 3 extubations with only 1 intubation.
  • We don’t always extubate for those that are ill and have cardiac arrest and die, we often leave the ETT in

Related articles

Related articles: