Query check CCI TISS time means must be two: Difference between revisions

From CCMDB Wiki
Jump to navigation Jump to search
(summarized and added request for Julie to confirm)
No edit summary
 
(6 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Data Integrity Check
{{Data Integrity Check
| DIC_summary = If certain [[Px Date]]s have a time component, then there should also be a matching [[CCI Picklist]] without the time
|DIC_summary=If certain [[Px Date]]s have a time component, then there should also be a matching [[CCI Picklist]] without the time
| DIC_related_concepts = CCI Picklist; CAM positive (TISS Item); Intracranial pressure monitoring (TISS Item); Vasoactive drug IV continuous-single (TISS Item); Vasoactive drug IV continuous-multiple simultaneous (TISS Item); Pulmonary arterial line (TISS Item); Peripheral arterial line (TISS Item); Central venous catheter (TISS Item); Invasive Mechanical Ventilation (TISS Item); Supp O2 through any device, delivered via nose, mouth, ETT or trach (TISS Item); Non-invasive CPAP or BIPAP (TISS Item); ETT Present (TISS Item); Trach Tube Present (TISS Item); IV hyperalimentation (TISS Item); Patient is on isolation (TISS Item)
|DIC_related_concepts=CCI Picklist; CAM positive (TISS Item); Intracranial pressure monitoring (TISS Item); Vasoactive drug IV continuous-single (TISS Item); Vasoactive drug IV continuous-multiple simultaneous (TISS Item); Pulmonary arterial line (TISS Item); Peripheral arterial line (TISS Item); Central venous catheter (TISS Item); Invasive Mechanical Ventilation (TISS Item); Supp O2 through any device, delivered via nose, mouth, ETT or trach (TISS Item); Non-invasive CPAP or BIPAP (TISS Item); ETT Present (TISS Item); Trach Tube Present (TISS Item); IV hyperalimentation (TISS Item); Patient is on isolation (TISS Item)
| DIC_firmness = soft check  
|DIC_firmness=soft check
| DIC_timing = complete
|DIC_timing=complete
| DIC_app = CCMDB.accdb
|DIC_coding=query ''check_CCI_TISS_time_means_must_be_two''
| DIC_coding = query ''check_CCI_TISS_time_means_must_be_two''
|DIC_implementation_date=2023-05-04
| DIC_status = needs review
|DIC_status=declined
| DIC_implementation_date =  
|DIC_app=CCMDB.accdb
|DIC_backlogged=No
}}
}}
== Rationale ==
== Rationale ==
For certain [[CCI Picklist]] entries, if a patient changes units on a day and if the procedure continues, there should be two CCI entries, one with a date and one without. Julie noticed a pattern of errors where the entry with a time is made, but the entry without a time is not present. While that could be correct, chart reviews showed that the untimed entry is often just forgotten. So, we decided to put in place a check that will flag records that have a timed CCI entry but no matching un-timed CCI entry for one of the following CCI codes:  
For certain [[CCI Picklist]] entries, if a patient changes units on a day and if the procedure continues, there should be two CCI entries, one with a date and one without. Julie noticed a pattern of errors where the entry with a time is made, but the entry without a time is not present. While that could be correct, chart reviews showed that the untimed entry is often just forgotten. So, we decided to put in place a check that will flag records that have a timed CCI entry but no matching un-timed CCI entry for one of the following CCI codes:  
Line 29: Line 29:
This check will be a '''soft-check''' since it is possible for these things to be correct.  
This check will be a '''soft-check''' since it is possible for these things to be correct.  


This check will be done on '''complete records only''' because this data should not be used on incomplete records and collectors may put in inconsistent data as they review.  
This check will be done on '''complete records only''' because in incomplete records, the collectors may put in inconsistent data as they review.
 
{{DJ|
* Can you confirm that what I described above is what you have in mind? [[User:Ttenbergen|Ttenbergen]] 16:27, 2022 December 1 (CST)
}}
 
{{TT| _dev_CCMDB
* summarized discussion, waiting for confirmation from Julie
}}


== Log ==
== Log ==
* 2023-05-30 - declined the check, it was causing too many false positives (as discussed with Lisa and Julie)
* 2023-05-04 - implemented
* 2021-09-01 - requirement identified but there are questions
* 2021-09-01 - requirement identified but there are questions



Latest revision as of 13:57, 2023 May 30

Data Integrity Checks
Summary: If certain Px Dates have a time component, then there should also be a matching CCI Picklist without the time
Related: CCI Picklist, CAM positive (TISS Item), Intracranial pressure monitoring (TISS Item), Vasoactive drug IV continuous-single (TISS Item), Vasoactive drug IV continuous-multiple simultaneous (TISS Item), Pulmonary arterial line (TISS Item), Peripheral arterial line (TISS Item), Central venous catheter (TISS Item), Invasive Mechanical Ventilation (TISS Item), Supp O2 through any device, delivered via nose, mouth, ETT or trach (TISS Item), Non-invasive CPAP or BIPAP (TISS Item), ETT Present (TISS Item), Trach Tube Present (TISS Item), IV hyperalimentation (TISS Item), Patient is on isolation (TISS Item)
Firmness: soft check
Timing: complete
App: CCMDB.accdb
Coding: query check_CCI_TISS_time_means_must_be_two
Uses L Problem table: not relevant for this app
Status: declined
Implementation Date: 2023-05-04
Backlogged: No
  • Cargo


  • SMW


  • Categories: 
  • form:

Rationale

For certain CCI Picklist entries, if a patient changes units on a day and if the procedure continues, there should be two CCI entries, one with a date and one without. Julie noticed a pattern of errors where the entry with a time is made, but the entry without a time is not present. While that could be correct, chart reviews showed that the untimed entry is often just forgotten. So, we decided to put in place a check that will flag records that have a timed CCI entry but no matching un-timed CCI entry for one of the following CCI codes:

This check will be a soft-check since it is possible for these things to be correct.

This check will be done on complete records only because in incomplete records, the collectors may put in inconsistent data as they review.

Log

  • 2023-05-30 - declined the check, it was causing too many false positives (as discussed with Lisa and Julie)
  • 2023-05-04 - implemented
  • 2021-09-01 - requirement identified but there are questions

Related articles

Related articles: