Ventilator Associated Pneumonia (VAP) Rate is the number of VAP cases per 1000 invasive ventilator days

Indicators
Indicator: Ventilator Associated Pneumonia (VAP) Rate
Created/Raw: Created
Program: not stated
Start Date: Jan 1 2013
End Date:
Reports: Critical Care Program Quality Indicator Report, Directors Quarterly and Annual Report (Critical Care), STB ICUs VAP Rate, CLIBSI Rate Summary, WRHA ICU Hospital-Acquired Conditions


  • Cargo


  • SMW:
    • "not stated" is not in the list (Critical Care, Medicine, Critical Care and Medicine) of allowed values for the "IndicatorProgram" property.
  • Categories
  • Default form:

QI domain

  • Safe

Reported as

Number of VAP per 1000 Ventilator-days

Significance

  • VAP is a device-associated infection, the device being the artificial airway-ventilator-circuit system. VAP defined using CDC definition. VAP is associated with worse patient outcomes and higher costs.
  • Factors affecting the incidence of VAP include those from patients (severity of illness, comorbidities, etc.) and processes of care.
  • VAP rate is a measure of the incidence of VAP.

Sampling Plan / Procedure

Inclusion Criteria

  • 100% sampling for all patients on invasive mechanical ventilation via ET Tube or tracheostomy
  • 100% sampling for all cases with VAP incidence.

Exclusion Criteria

Exclude non-invasive ventilation.

Frequency

  • Daily occupancy of patients who stayed in ICU
  • Daily recording of dates of patient being on invasive mechanical ventilation
  • Total occupancy in terms of patient days are calculated and reported on a monthly, quarterly or yearly basis based on the daily data.
  • Total number of ventilated days are calculated and reported on a monthly, quarterly or yearly basis based on the daily data.
  • Time Reference is calendar month, quarter or year.

Definition and Derivation

Numerator

Num = Total Invasive Mechanical Vent Days in a calendar period

Denominator

Denom =Total Patient Days on the same period as the numerator

Formula

VUR = Num / Denom * 100

Example

  • Time Reference: Calendar Dates from Jan 1, 2017 to March 31, 2017
  • Total days patients are on invasive ventilator = 830
  • Total patient days from Jan 1, 2017 to March 31, 2017 at HSC MICU = 1103.7
  • VUR (%) = 830 / 1103.7 = 75.2%

Data Sources

  • Daily data for Invasive are taken on TISS28 element #18. The TISS form is being marked daily by ICU bed side nurses and quality checked by the Database Data Collectors.
  • Daily occupancy per day are derived from Accept DtTm or Arrive DtTm and Dispo DtTm.

SAS Program