The '''AP Sys [[BP]]''' data input field records '''SYSTOLIC''' blood pressure value.
{{Data element
|field_name=Ap_APSysBP
|CCMDB_label=APSysBP
|CCMDB_tab=Apache
|in_table=L Log table
|data_type=number
|datafield_length=single
|program_collecting=CC
|created_raw=Raw
|data_element_sort_index=59
|element_description=Ap_SysBP is the systolic blood pressure.
}}
== Different instructions for ICU and Medicine ==
The details of collection for ICU and medicine are different. For the timing and which value to use, see:
* for ICU: [[Mean BP]]
* for medicine: [[ALERT Scale]]


If a value for this is not available, follow the [[Apache II General Collection Guidelines#Missing Values Rule for APACHE II | missing value rule]].
{{APACHE physiological variable
|AP phys name= Systolic Blood Pressure
|AP phys unit= mmHG
|AP phys absMax= 360
|AP phys warnMax= 243
|AP 0= as per [[Mean BP]]
|AP phys warnMin= 49
|AP phys absMin= 25
}}


==Medicine==
== Data use ==
Apache Systolic [[BP]] is used for the '''[[:Category: MOST | MOST]]''' score.
Apache Systolic [[BP]] is used for the '''[[ALERT Scale]]''' score.
*for MOST - Value selected is one that is "'''closest to the time'''" just prior to when the medicine service physician "accepts" the patient to the medicine service.


==Critical Care==
== Data Integrity Checks ==
*It is also one of the values used to calculate the [[Mean BP | Mean BP]] for [[:category:APACHE II|APACHE II]].
{{Data Integrity Check List}}
**for selecting [[BP]] values for [[APACHE II]], please refer to: [[Mean BP | Mean BP]]
==Blood Pressure when on IAPB (intra aortic balloon pump)==
*If on IABP, use peripheral arterial BP, NOT aortic pressure.  We want the worst value in the 1st 24 hrs in ICU, so if possible it would be PRE IABP BP.  If pt comes out of OR with IABP use peripheral arterial BP not aortic BP.--[[User:Agarland|Dr. Allan Garland]], Dr. Bojan Paunovic, --[[User:TOstryzniuk|TOstryzniuk]] 16:28, 31 January 2011 (CST)


== Data Integrity Rules ==
The AP Sys [[BP]] must be >=25 And <=360.


 
[[Category:Blood Pressure-APACHE]]
[[Category:APACHE II Physiological Variables]]
[[Category:ALERT Scale Elements]]
[[Category: Blood Pressure-APACHE]]
[[Category: MOST Score Elements]]
[[Category: Data Integrity Rules]]