Transfusion Audit: Difference between revisions
TOstryzniuk (talk | contribs) |
Ttenbergen (talk | contribs) m Text replacement - "[[Category: " to "[[Category:" |
||
| (32 intermediate revisions by 2 users not shown) | |||
| Line 1: | Line 1: | ||
{{Project | |||
|ProjectActive=legacy | |||
|ProjectProgram=CC | |||
|ProjectRequestor=Unknown/legacy | |||
|ProjectCollectionStartDate=2007-11-01 | |||
|ProjectCollectionStopDate=2008-01-31 | |||
|Project={{PAGENAME}} | |||
}} | |||
Legacy only, see below for details | |||
==Purpose== | ==Purpose== | ||
*to audit the appropriateness of RBC transfusion practices in the ICU. | *to audit the appropriateness of RBC transfusion practices in the ICU. | ||
== | ==Audit Dates== | ||
*2004/2005 | *Random audits | ||
'''2004/2005''' | |||
*'''STB''' (May 1.04 to Jun 30.05) SICU & MICU | |||
*'''HSC''' (Jan to Jun 30.05) SICU & MICU | |||
'''2007/2008''' | |||
*'''all ICU's''' in City of Winnipeg (exclude CCU & IICU) (Nov 1.07 to Jan 31.08) | |||
Data can be found on: '''{{S:\MED\MED_CCMED}}CCMDB_Special_Projects\Transfusion\2004_2005_TRANSFUSION''' | |||
==Amendments to transfusion collection process guidelines:== | ==Amendments to transfusion collection process guidelines:== | ||
| Line 15: | Line 45: | ||
*If two or more units of PC are ordered to be given consecutively in a row and there is no Hgb level drawn between each unit of PC’s, record the same Hgb level that you used for the first PC transfused and in the comment section for the second PC transfused type: same Hgb. | *If two or more units of PC are ordered to be given consecutively in a row and there is no Hgb level drawn between each unit of PC’s, record the same Hgb level that you used for the first PC transfused and in the comment section for the second PC transfused type: same Hgb. | ||
*'''This data needs to be completed as soon as possible for '''''all''''' patients, not only those who are being sent, since the data is sent for all patients every time data is sent. ''' | |||
==APPROPRIATE Transfusion if following Criteria is met:== | ==APPROPRIATE Transfusion if following Criteria is met:== | ||
| Line 36: | Line 68: | ||
5. '''INAPPROPRIATE''' Transfusion if: | 5. '''INAPPROPRIATE''' Transfusion if: | ||
If criteria 1 to 4 above not met | |||
==THE RULES== | ==THE RULES== | ||
How to prioritize your selection if “two reasons” for the transfusion of a unit of Packed Cells exist at the same time. | How to prioritize your selection if “two reasons” for the transfusion of a unit of Packed Cells exist at the same time. | ||
IF patient meets the following two criteria at the same time: | IF patient meets the following two criteria at the same time: | ||
*(1)Hgb 70 or less + | *(1) Hgb 70 or less + | ||
*(2)ACS | *(2) ACS | ||
**Then choose item 1. Hgb 70 or less as the reason for transfusion. | **Then choose item 1. Hgb 70 or less as the reason for transfusion. | ||
OR | OR | ||
1 | *(1) Hgb 70 or less + | ||
3 | *(3) Active bleed | ||
Then choose item 1. Hgb 70 or less as the reason for transfusion. | **Then choose item 1. Hgb 70 or less as the reason for transfusion. | ||
OR | OR | ||
1 | *(1) Hgb 70 or less + | ||
4 | *(4) Septic Shock | ||
Then choose item 1. Hgb 70 or less as the reason for transfusion. | **Then choose item 1. Hgb 70 or less as the reason for transfusion. | ||
==More RULES.....== | ==More RULES.....== | ||
Hgb 71 or more + | *Hgb 71 or more + | ||
2. ACS + | **2. ACS + | ||
3. Active bleed. | **3. Active bleed. | ||
If both DX, then choose 3. Active bleed | If both DX, then choose 3. Active bleed | ||
Hgb 71 or more + | *Hgb 71 or more + | ||
2. ACS + | **2. ACS + | ||
4. Septic shock. | **4. Septic shock. | ||
If both DX, then choose 4. Septic Shock | If both DX, then choose 4. Septic Shock | ||
Hgb 71 or more + | *Hgb 71 or more + | ||
3. Active bleed + | **3. Active bleed + | ||
4. Septic Shock | **4. Septic Shock | ||
If both DX, then choose 3. Active bleed | If both DX, then choose 3. Active bleed | ||
| Line 81: | Line 113: | ||
3. Quality checking the total number of PC transfusion with LAB data | 3. Quality checking the total number of PC transfusion with LAB data | ||
*For all patients admitted on Nov 1.07 and discharged on for before Feb 3.08 the total number of PC’s transfused should equal to total number of PC tallied in your Lab data. Please make sure you do this cross check before you send in files. | *For all patients admitted on Nov 1.07 and discharged on for before Feb 3.08 the total number of PC’s transfused should equal to total number of PC tallied in your Lab data. Please make sure you do this [[cross check]] before you send in files. (ACCESS takes care of this data integrity check now). | ||
[[Category:L_TmpV2 Data]] | |||
[[Category:QA]] | |||