AP Sys BP Field: Difference between revisions
Ttenbergen (talk | contribs) m clean-up |
Ttenbergen (talk | contribs) m clean up and centralizing |
||
| Line 1: | Line 1: | ||
The '''AP Sys [[BP]]''' data input field records '''systolic''' blood pressure value. | |||
The | The field is related to [[AP Dias BP Field]]; '''although they are separate fields they must come from same reading!''' | ||
The details of collection for ICU and medicine are different. For the timeing and which value to use, see: | |||
* for ICU: [[General Collection Guidelines for Apache II#When to collect, which value to use]] | |||
* for medicine: [[MOST score timing of assessment]] | |||
==Critical Care== | ==Critical Care== | ||
Refer to '''[[Mean BP]]''' for information on collection Systolic BP for critical care. | Refer to '''[[Mean BP]]''' for information on collection Systolic BP for critical care. | ||
== Blood Pressure when on IAPB (intra aortic balloon pump) == | |||
We want the worst value in the 1st 24 hrs in ICU, so if possible get the '''pre IABP BP'''. | We want the worst value in the 1st 24 hrs in ICU, so if possible get the '''pre IABP BP'''. | ||
If only post IABP BPs are available, use peripheral arterial BP, '''not''' aortic pressure. | If only post IABP BPs are available, use peripheral arterial BP, '''not''' aortic pressure. | ||
== Data use == | |||
Apache Systolic [[BP]] is used for the '''[[:Category: MOST | MOST]]''' score. | |||
This is one of the values used to calculate the [[Mean BP | Mean BP]] for [[:category:APACHE II|APACHE II]]. | |||
== {{CCMDB Data Integrity Checks}} == | == {{CCMDB Data Integrity Checks}} == | ||