Creatinine (APACHE): Difference between revisions
Jump to navigation
Jump to search
Ttenbergen (talk | contribs) m m |
Ttenbergen (talk | contribs) m Text replacement - "| element_description" to "| CCMDB_tab = Apache | element_description" |
||
(3 intermediate revisions by 2 users not shown) | |||
Line 2: | Line 2: | ||
| field_name = Ap_Creat | | field_name = Ap_Creat | ||
| CCMDB_label = Creatinine | | CCMDB_label = Creatinine | ||
| element_description = | | CCMDB_tab = Apache | ||
| in_table = L_Log | | element_description = The patient's {{#show: Creatinine | ?AP phys name}} level in {{#show: Creatinine | ?AP phys unit}}. | ||
| in_table = L_Log table | |||
| data_type = number | | data_type = number | ||
| datafield_length = single | | datafield_length = single | ||
Line 10: | Line 11: | ||
| data_element_sort_index = 76 | | data_element_sort_index = 76 | ||
}} | }} | ||
[http://en.wikipedia.org/wiki/Creatinine Creatinine] | |||
{{APACHE physiological variable | |||
|AP phys name=serum creatinine | |||
|AP phys unit=µmol/L | |||
|AP phys absMax= | |||
== | |AP phys warnMax= | ||
|AP H4= >=309 | |||
|AP H3= >=178 and <309 | |||
|AP H2= >=133 and <178 | |||
|AP 0= >=53 and <133 | |||
|AP L2= ≤52 | |||
|AP phys warnMin= 5 | |||
|AP phys absMin= 2 | |||
}} |
Latest revision as of 00:36, 2019 January 3
Data Element (edit) | |
Field Name: | Ap_Creat |
CCMDB Label: | Creatinine |
CCMDB tab: | Apache |
Table: | L_Log table |
Data type: | number |
Length: | single |
Program: | CC |
Created/Raw: | Raw |
Start Date: | 1988-07-11 |
End Date: | 2300-01-01 |
Sort Index: | 76 |
The patient's level in .
Apache Physiological Variable | |
variable name | serum creatinine |
unit | µmol/L |
absolute max allowed | |
warning max | |
high score 4 | >=309 |
high score 3 | >=178 and <309 |
high score 2 | >=133 and <178 |
high score 1 | |
score 0 | >=53 and <133 |
low score 1 | |
low score 2 | ≤52 |
low score 3 | |
low score 4 | |
AP phys warnMin | 5 |
AP phys absMin | 2 |
APACHE Score
This value is used to generate the APACHE Score.
Collecting Apache physiological variables
There are some specific rules to follow in choosing which one of several lab results to collect.
See APACHE physiological variable collection for details.
Cross Chcks
Rules described in APACHE_physiological_variable_collection#Exceptionally_high_or_low_values are implemented by Check APACHE physiological variable high low.