HR: Difference between revisions

From CCMDB Wiki
Jump to navigation Jump to search
m (apache template)
m (m)
Line 1: Line 1:
{{Data_element
| field_name = Ap_HeartRate
| CCMDB_label = Heart Rate
| element_description = Patient's heart rate in beats per minute.
| in_table = L_Log
| data_type = number
| datafield_length = single
| program_collecting = CC
| created_raw = Raw
| data_element_sort_index = 61
}}
== Different instructions for ICU and Medicine ==
The details of collection for ICU and medicine are different. For the timing and which value to use, see:
* for ICU: [[General Collection Guidelines for Apache II#When to collect, which value to use]]
* for medicine: [[MOST score timing of assessment]]
== Atrial Fibrillation ==
When the patient is in atrial fibrillation, do not use the atrial rate use the ventricular rate.
{{APACHE physiological variable
{{APACHE physiological variable
|AP phys name=Heart Rate
|AP phys name=Heart Rate
Line 14: Line 34:
|AP phys absMin=5
|AP phys absMin=5
}}
}}
{{Data_element
| field_name = Ap_HeartRate
| CCMDB_label = Heart Rate
| element_description = Patient's heart rate in beats per minute.
| in_table = L_Log
| data_type = number
| datafield_length = single
| program_collecting = CC
| created_raw = Raw
| data_element_sort_index = 61
}}
<onlyinclude></onlyinclude>
The details of collection for ICU and medicine are different. For the timeing and which value to use, see:
* for ICU: [[General Collection Guidelines for Apache II#When to collect, which value to use]]
* for medicine: [[MOST score timing of assessment]]


== Atrial Fibrillation ==
When the patient is in atrial fibrillation, do not use the atrial rate use the ventricular rate.


== {{CCMDB Data Integrity Checks}} ==
* Must be (>=10 And <=250)


[[Category: APACHE II Physiological Variables]]
[[Category: MOST Score Elements]]
[[Category: MOST Score Elements]]

Revision as of 23:51, 2017 January 7

Data Element (edit)
Field Name: Ap_HeartRate
CCMDB Label: Heart Rate
CCMDB tab: not stated
Table: L_Log
Data type: number
Length: single
Program: CC
Created/Raw: Raw
Start Date: 1988-07-11
End Date: 2300-01-01
Sort Index: 61

Patient's heart rate in beats per minute.

  • SMW

Legacy implementation right in the table

  • Cargo


  • Categories
  • Forms


Different instructions for ICU and Medicine

The details of collection for ICU and medicine are different. For the timing and which value to use, see:

Atrial Fibrillation

When the patient is in atrial fibrillation, do not use the atrial rate use the ventricular rate.


Apache Physiological Variable
variable name Heart Rate
unit bpm
absolute max allowed 205
warning max 250
high score 4 >=180
high score 3 >=140 and <180
high score 2 >=110 and <140
high score 1
score 0 >=70 and <110
low score 1
low score 2 >=55 and <70
low score 3 >=40 and <55
low score 4 <40
AP phys warnMin 10
AP phys absMin 5

APACHE Score

This value is used to generate the APACHE Score.

Collecting Apache physiological variables

There are some specific rules to follow in choosing which one of several lab results to collect.

See APACHE physiological variable collection for details.

Cross Chcks

Rules described in APACHE_physiological_variable_collection#Exceptionally_high_or_low_values are implemented by Check APACHE physiological variable high low.