TISS76-Cardiovascular: Difference between revisions
Jump to navigation
Jump to search
TOstryzniuk (talk | contribs) m New page: TISS Category: TISS |
TOstryzniuk (talk | contribs) mNo edit summary |
||
| Line 1: | Line 1: | ||
TISS | === TISS Cardiovascular === | ||
TISS therapeutic variables: T9 to T25 | |||
* 9 - ECG monitoring | |||
* 10 - Hourly Vital signs -Minimum 6 hrs consecutively in the first 24 hrs in ICU to get points | |||
* 11 - Peripheral arterial line | |||
* 12 - Pulmonary arterial line | |||
* 13 - Measurement of CVP (any method) | |||
* 14 - Measurement of Cardiac Output | |||
* 15 - Temporary Pacemaker-'''Standby''' (includes external) - wires hooked up but pace not turned on. | |||
* 16 - Temporary Pacemaker-'''Active''' (includes external) - turned on but may not be pacing all the time. | |||
** The testing for "capture" not counted as active pacing. | |||
**Permanent pacer not included. | |||
* 17 - Post Cardiac Arrest - (first 48 hours) mark for 2 days | |||
* 18 - Cardioversion/Defibrillation - While in ICU only | |||
* 19 - IABP | |||
**NOTE: Community hospitals (Oaks, Grace, Concordia, Victoria). If a patient goes from your center to STB or HSC for an angiogram/plasty, has an IABP inserted in the angio department and is either admitted for HSC or STB ICU/CCU or goes directly to the OR from there, please do not put on your TISS item # 19 -IABP.Discharge to should be coded using the codes for HSC or STB for OR , CCU , SICU or MICU. | |||
[[Category: TISS]] | [[Category: TISS]] | ||
Revision as of 23:21, 29 January 2009
TISS Cardiovascular
TISS therapeutic variables: T9 to T25
- 9 - ECG monitoring
- 10 - Hourly Vital signs -Minimum 6 hrs consecutively in the first 24 hrs in ICU to get points
- 11 - Peripheral arterial line
- 12 - Pulmonary arterial line
- 13 - Measurement of CVP (any method)
- 14 - Measurement of Cardiac Output
- 15 - Temporary Pacemaker-Standby (includes external) - wires hooked up but pace not turned on.
- 16 - Temporary Pacemaker-Active (includes external) - turned on but may not be pacing all the time.
- The testing for "capture" not counted as active pacing.
- Permanent pacer not included.
- 17 - Post Cardiac Arrest - (first 48 hours) mark for 2 days
- 18 - Cardioversion/Defibrillation - While in ICU only
- 19 - IABP
- NOTE: Community hospitals (Oaks, Grace, Concordia, Victoria). If a patient goes from your center to STB or HSC for an angiogram/plasty, has an IABP inserted in the angio department and is either admitted for HSC or STB ICU/CCU or goes directly to the OR from there, please do not put on your TISS item # 19 -IABP.Discharge to should be coded using the codes for HSC or STB for OR , CCU , SICU or MICU.