BRR: Difference between revisions

From CCMDB Wiki
Jump to navigation Jump to search
TOstryzniuk (talk | contribs)
TOstryzniuk (talk | contribs)
Line 38: Line 38:
{{Discussion}}
{{Discussion}}
*[[http://ltc.umanitoba.ca/wikis/ccmdb/index.php/CCMDB.mdb_Change_Log_2009#BRR.2C_XBR_.26_T6 CHANGE REQUEST LOG 2009 for CCMDB.mdb and for Data cleaner]]--[[User:TOstryzniuk|TOstryzniuk]] 16:03, 28 January 2009 (CST).   
*[[http://ltc.umanitoba.ca/wikis/ccmdb/index.php/CCMDB.mdb_Change_Log_2009#BRR.2C_XBR_.26_T6 CHANGE REQUEST LOG 2009 for CCMDB.mdb and for Data cleaner]]--[[User:TOstryzniuk|TOstryzniuk]] 16:03, 28 January 2009 (CST).   
**Not sure where it went from the above mentioned link, but rule is now here in this article. Tina you can take this discussion out of this article when you have dealt with it on the request for change log 2009.  I think you have in the newer version of ACCESS but it has not been tested.  --[[User:TOstryzniuk|TOstryzniuk]] 16:37, 19 March 2009 (CDT)
 





Revision as of 14:09, 2009 April 3

BRR is a ICU Var 2 tag that we use in our database for ICU patients who have been placed on the Cardiac Arrest Cooling Protocol

  • BRR - stands for "Brrrr" as in shivering or cold.

Possible values

  • BRR - mean cooling protocol applied for cardiac arrest (started August 2004).
  • XBR - means no cooling protocol applied for cardiac arrest (Added March 19.09)

Cardiac Arrest Cooling Protocol

  • Target temp: 32°C to 34°C for 12 to 24 hours.
  • Code is not to be applied when a cooling protocol is used to normalize temperature for non-arrested patients.

Taken from the Hypothermia Protocol:

  • Cooling is indicated if ALL of the following are checked:
    • Witnessed Arrest (Dx code: 100-2)
    • Initial rhythm ventricular fibrillation/tachycardia(Dx code: 131-4, or 131-1)
    • Time to ACLS <15 minutes
    • Total ACLS time <60 minutes
    • Persistent GCS < or = 9
    • Systolic BP currently over 90 mmHg (pressors allowed)
    • < 8 hours elapsed since Return of Spontaneous Circulation (ROSC)

--LKolesar 13:54, 22 January 2009 (CST) --TOstryzniuk 20:37, 26 January 2009 (CST)


Data Integrity Rules

AND


By marking BRR or BRX for all with DX of 100-2, collectors will have verified at the time of collection that they did not miss marking Var 2, and this will reduce the query's that gets send back for double checking.--TOstryzniuk 21:46, 18 March 2009 (CDT)