{{Data_element
| field_name = ___
| CCMDB_label = ___
| element_description = Mean Blood Pressure defined by round(((2x Diastolic) + Systolic)) ÷ 3)
| in_table = ___
| data_type = number
| datafield_length = single
| program_collecting = CC
| created_raw = Created
| data_element_sort_index = ___
}}
The '''mean''' Blood Pressure [[BP]] as collected for the APACHE II score is calculated as follows:  
The '''mean''' Blood Pressure [[BP]] as collected for the APACHE II score is calculated as follows:  
  Mean BP = round(((2x Diastolic) + Systolic)) ÷ 3)
  Mean BP = round(((2x Diastolic) + Systolic)) ÷ 3)

Revision as of 22:51, 3 January 2017

Data Element (edit)
Field Name: ___
CCMDB Label: ___
CCMDB tab: not stated
Table: [[___]]Property "InTable" (as page type) with input value "___" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process.[[Category:___]]
Data type: number
Length: single
Program: CC
Created/Raw: Created
Start Date: 1988-07-11
End Date: 2300-01-01
Sort Index: ___"___" is not a number.

Mean Blood Pressure defined by round(((2x Diastolic) + Systolic)) ÷ 3)

  • SMW

Legacy implementation right in the table

  • Cargo


  • Categories
  • Forms


The mean Blood Pressure BP as collected for the APACHE II score is calculated as follows:

Mean BP = round(((2x Diastolic) + Systolic)) ÷ 3)

Rounding may not be part of the original definition of Mean BP, but it is how we do it in order to get integers that work with the Apache Ranges.

Collection Instructions for mean arterial BP

artificially changed BPs

See General Collection Guidelines for Apache II#When to collect for which value to use. We don't want values that are changed by interventions already, for example if a patient is in septic shock, you would want the lowest BP as opposed to the highest BP that is artificially enhanced by inotropes.

Blood Pressure when on IAPB (intra aortic balloon pump)

We want the worst value in the 1st 24 hrs in ICU, so if possible get the pre IABP BP.

If only post IABP BPs are available, use peripheral arterial BP, not aortic pressure.