''See also: [[AP Sys BP Field]]; '''although they are separate fields they must come from same reading!'''''
The '''AP Sys [[BP]]''' data input field records '''systolic''' blood pressure value.


The '''AP Sys [[BP]]''' data input field records '''SYSTOLIC''' blood pressure value.
The field is related to [[AP Dias BP Field]]; '''although they are separate fields they must come from same reading!'''


If a value for this is not available, follow the [[Apache II General Collection Guidelines#Missing Values Rule for APACHE II | missing value rule]].
The details of collection for ICU and medicine are different. For the timeing and which value to use, see:
 
* for ICU: [[General Collection Guidelines for Apache II#When to collect, which value to use]]
==Medicine==
* for medicine: [[MOST score timing of assessment]]
Select value '''closest to the time''' just prior to when the medicine service physician "accepts" the patient to the medicine service.
 
For direct transfers to Medicine via the ER use the first BP taken and recorded on the Triage record.
 
Apache Systolic [[BP]] is used for the '''[[:Category: MOST | MOST]]''' score.


==Critical Care==
==Critical Care==
Refer to '''[[Mean BP]]''' for information on collection Systolic BP for critical care.  
Refer to '''[[Mean BP]]''' for information on collection Systolic BP for critical care.  


This is one of the values used to calculate the [[Mean BP | Mean BP]] for [[:category:APACHE II|APACHE II]].
== Blood Pressure when on IAPB (intra aortic balloon pump) ==
 
=== Blood Pressure when on IAPB (intra aortic balloon pump) ===
We want the worst value in the 1st 24 hrs in ICU, so if possible get the '''pre IABP BP'''.  
We want the worst value in the 1st 24 hrs in ICU, so if possible get the '''pre IABP BP'''.  


If only post IABP BPs are available, use peripheral arterial BP, '''not''' aortic pressure.  
If only post IABP BPs are available, use peripheral arterial BP, '''not''' aortic pressure.  
== Data use ==
Apache Systolic [[BP]] is used for the '''[[:Category: MOST | MOST]]''' score.
This is one of the values used to calculate the [[Mean BP | Mean BP]] for [[:category:APACHE II|APACHE II]].


== {{CCMDB Data Integrity Checks}} ==
== {{CCMDB Data Integrity Checks}} ==

Revision as of 13:46, 2016 April 27

The AP Sys BP data input field records systolic blood pressure value.

The field is related to AP Dias BP Field; although they are separate fields they must come from same reading!

The details of collection for ICU and medicine are different. For the timeing and which value to use, see:

Critical Care

Refer to Mean BP for information on collection Systolic BP for critical care.

Blood Pressure when on IAPB (intra aortic balloon pump)

We want the worst value in the 1st 24 hrs in ICU, so if possible get the pre IABP BP.

If only post IABP BPs are available, use peripheral arterial BP, not aortic pressure.

Data use

Apache Systolic BP is used for the MOST score.

This is one of the values used to calculate the Mean BP for APACHE II.

Template:CCMDB Data Integrity Checks

The AP Sys BP must be >=25 And <=360.