Ventilated patient flow: Difference between revisions

From CCMDB Wiki
Jump to navigation Jump to search
No edit summary
 
(16 intermediate revisions by 2 users not shown)
Line 8: Line 8:
}}
}}


Used in aggregate form as "per location" and/or "per timeframe", e.g. by month/quarter/year x Ward/Unit x Hospital.
==QI domain==
==QI domain==
* Efficient  
* [[QualityDomain::Efficient]]


==Reported as==
==Reported as==
Count of patients on mechanical ventilation per bed per period of time
Count of patients on mechanical ventilation per bed per time frame


==Significance==
==Significance==
Line 19: Line 20:
==Sampling Plan / Procedure==
==Sampling Plan / Procedure==
===Inclusion Criteria===
===Inclusion Criteria===
100% sampling for all patients on mechanical ventilation. Mechanical ventilation includes:
Same as [[Duration of Mechanical Ventilation]]
* Invasive Mechanical Ventilation via ET Tube or tracheostomy
 
* Non-invasive CPAP or BIPAP
===Exclusion Criteria===
===Exclusion Criteria===
Patients who are not on mechanical ventilation
Same as [[Duration of Mechanical Ventilation]]
===Frequency===
===Frequency===
* Daily recording of dates of patient being on mechanical ventilation
* Same as [[Duration of Mechanical Ventilation]]
* Total number of ICU discharges being on mechanical ventilation at least one day during the ICU stay are calculated and reported on a monthly, quarterly or yearly basis based on the daily data.
* The number of beds opened per unit is taken from the [[Bed Census]] Database.
* Time Reference for month, quarter or year is based on  ICU discharge dates.
* Number of physical ICU beds available. The number of available bed rarely change except for pandemic or seasonal closures.
** If the number of daily available bed changes over the period of time, use the number of bed which is the most numbered. Example, in a monthly period,  20 out of 30 days have opened bed = 15 while 10 days have 14 beds, use the number of bed=15.  


==Definition and Derivation==
==Definition and Derivation==
===Numerator===
===Numerator===
Num = Total number of discharges who were ventilated at any time during the ICU stay
Num = Total number of discharges who were mechanically ventilated at any time during the ICU stay
===Denominator===
===Denominator===
Denom = Number of ICU beds  
Denom = Number of ICU beds  
Line 45: Line 42:


==Data Sources==
==Data Sources==
Daily data for Invasive and non invasive mechanical ventilation are taken on [[TISS28]] elements #18 and #21 respectively.  The TISS form is being marked daily by ICU bed side nurses and quality checked by the Database Data Collectors.
*Same as [[Duration of Mechanical Ventilation]].
The daily bed available or opened per unit is taken from the Bed Census Database.  
*The number bed opened per unit is taken from the [[Bed Census]] Database.


==SAS Program==
==SAS Program==
Part of X:\Julie\SAS_CFE\CC_reports\ChartReport\prepCCChart.sas
S:\MED\MED_CCMED\Julie\SAS_CFE\CFE_macros\Prep_CCI_TISS.sas
==Report Users==
Part of X:\Julie\SAS_CFE\CC_reports\ChartReport\prepCCChart.sas  
*Critical Care Directors and Site Managers
===Report Users===
*Critical Care Quality Improvement Team (QIT)
Critical Care Directors and Site Managers
 
Critical Care Quality Improvement Team (QIT)
 
[[Category:TISS28]]
[[Category:TISS28]]
[[Category: Data Use]]
[[Category: Data Use]]
[[Category: Reporting]]
[[Category: Reporting]]
[[Category: Statistical Analysis]]
[[Category: Statistical Analysis]]

Latest revision as of 14:27, 2022 January 11

Ventilated Patient Flow is the number of mechanically ventilated patients at any time during the ICU stay per bed per period of time.

Indicators
Indicator: Ventilated Patient Flow
Created/Raw: Created
Program: Critical Care
Start Date: Jan 1 2013
End Date:
Reports: Critical Care Program Quality Indicator Report


  • Cargo


  • SMW:
  • Categories
  • Default form:

Used in aggregate form as "per location" and/or "per timeframe", e.g. by month/quarter/year x Ward/Unit x Hospital.

QI domain

  • Efficient

Reported as

Count of patients on mechanical ventilation per bed per time frame

Significance

Experience with mechanical ventilation is associated with improved patient outcomes. Factors affecting ventilated patient flow include ICU patient type and acuity, Structural and process-related aspects of care, and factors affecting patient flow following ICU care.

Sampling Plan / Procedure

Inclusion Criteria

Same as Duration of Mechanical Ventilation

Exclusion Criteria

Same as Duration of Mechanical Ventilation

Frequency

Definition and Derivation

Numerator

Num = Total number of discharges who were mechanically ventilated at any time during the ICU stay

Denominator

Denom = Number of ICU beds

Formula

Ventilated Patient Flow = Num / Denom

Example

  • Time Reference: Discharge Dates from Jan 1, 2017 to March 31, 2017
  • Number of patients who have discharge dates from Jan 1, 2017 to March 31, 2017 and who were on mechanical ventilation at HSC MICU = 158
  • Opened Bed = 15
  • Ventilated Patient Flow = 158 / 15 = 10.5

Data Sources

SAS Program

S:\MED\MED_CCMED\Julie\SAS_CFE\CFE_macros\Prep_CCI_TISS.sas Part of X:\Julie\SAS_CFE\CC_reports\ChartReport\prepCCChart.sas

Report Users

Critical Care Directors and Site Managers

Critical Care Quality Improvement Team (QIT)