==Project Name==
{{Project
|ProjectActive=legacy
|ProjectProgram=CC
|ProjectRequestor=Unknown/legacy
|ProjectCollectionStartDate=2011-01-01
|ProjectCollectionStopDate=2011-12-05
|Project={{PAGENAME}}
}}
Legacy only, see below for details
 
 
 
 
 
 
 
 
 
 
 
 
 
DeviseUse Study (this is the spelling of the study in our program and on the wiki)
DeviseUse Study (this is the spelling of the study in our program and on the wiki)


Line 7: Line 28:
==Who==
==Who==
Information to be collected from charts daily by Regional Database Team - Critical Care areas.
Information to be collected from charts daily by Regional Database Team - Critical Care areas.
*Monitoring being done by the [[:Category:Critical Care QI Team | Critical Care QI Team]] along with the cross Canada ICU collaborative project teams [[CCVSM]]. Members of the CCQI team will also provide ongoing support and feedback for issue related to collection of this data from chart.   
*Monitoring being done by the [[:Category:Critical Care QI Team | Critical Care QI Team]]. Members of the CCQI team will also provide ongoing support and feedback for issue related to collection of this data from chart.
*Only the ICU's in the city will be collecting this informationNo device use information will be collected at the CCU's at STB and HSC or the Cardiac ICU at STB.  IICU will collect this data. 
*[[User: LKolesar|Laura Kolesar]] will be the lead data collector who will work with CCQI team, [[Statistician]] & [[User:Ttenbergen | Tina Tenbergen]] on matters related to this project.
*[[User: LKolesar|Laura Kolesar]] will be the lead data collector who will work with CCQI team, [[Statistician]] & [[User:Ttenbergen | Tina Tenbergen]] on matters related to this project.


Line 18: Line 40:
*Information sent each week with sending to [[L TmpV2]] even though patient files is not complete.   
*Information sent each week with sending to [[L TmpV2]] even though patient files is not complete.   


=== discussion re. getting exact times ===
==Instructions for collecting==
{{Discussion}}
* Exact time is not necessary, approximate time is OK.
Because the DeviceUse data will be repeatedly send each week to L_TMPV2, the collectors must be precise when entering any dates and time for devices and not be putting dummy times in and keep changing them.  The statistician will be reporting this information weekly regardless if the rest of file is completed or not.  Will need to discuss this more later.
* The focus is to '''determine number of days with each device while in the unit''',but also we are tracking the number of times intubated during a stay. So all extubations and intubations need to be put in the list even if it is done the same day. 
*Is anyone else going to have a hard time getting precise '''times''' when entering the dates? I think this will be a challenge! [[User:GHall|GHall]] 20:26, 6 September 2011 (CDT)
* For each of the following devices, enter an in and out record or start and stop record for each device present:
** I wonder if the focus is on ''actual'' times rather than dummy ones; considering the paragraph then explains that the data will be sent every time, I would think that that is what this is about more than accuracy. [[User:Ttenbergen|Ttenbergen]] 09:38, 7 September 2011 (CDT)
** on "in" or "start" record, tick off "present on admission" instead of entering a date if the device is present on admission. The same goes for if the device is "present on discharge"  You need to put the "out" or "stop" option and then tick off "present on discharge".  To view this option, click on the "edit" button.
***We will pilot the process first and find out what the issue might be in obtaining this data and work them out before we actually launch.  The only way we will know if there will be issues dates and  in particular, times, is when we actually test the process first and find out.--[[User:TOstryzniuk|TOstryzniuk]] 17:52, 7 September 2011 (CDT)
*** if date is absent and the box is ticked , the Statistician will use the Admit Date/Time as the "in" or "start" date
****I think precise times will be hard to find. How precise do you want to be? This will definatly take some extra time to collect. Lois
*** if date is present and is different from Admit Date/Time, there is no need to tick the box.
 
** on "out" or "stop" record, tick off "present on discharge" instead of entering a date if the device is present on discharge
==Items Collected==
*** if date is absent and the box is ticked , the Statistician will use the Discharge Date/Time as the "out" or "stop" date
*Art line_IN - date & time
*** if date is present and is different from Discharge Date/Time, there is no need to tick the box.
*Art line_OUT - date & time
** devices:
 
*** Central line (first in and last out)
*'''1st''' Central line_IN - date & time
**** doesn't matter how many central lines a patient has at the same time (hint: if helps to keep track by writing in the note section which line it is for your own benefit.
*'''Last'''-Central line_OUT
*** PICC line when in and when out.
**NOTE:  It doesn't matter how many central lines a patient has each day. One patient with three central lines, line count is "one" line for that patient for that day.  
*** ETT in & vent start, use this option if both are simultaneous (if not use individual options which have a "Z" in front)
 
*** ETT out & vent stop, use this option if both are simultaneous (if not use individual options which have a "Z" in front)
*PICC line _IN - date & time
*** zETT in and out is used if done independently of vent.
*PICC line_OUT - date & time
*** zVent stop and start is used if done independently of ETT in and out. 
 
**** If an '''unplanned extubation''' occurs enter a record for this in addition to documenting the ETT out/vent stop records
*ETT_IN - date & time
*** Trach when in and when out.
*ETT_OUT - date & time - ('''bool_var''') unplanned extubation check mark means YES
*** BIPAP/CPAP start and stop  Changed title to BI/CPAP start/stop to make shorter
**uplanned extubation is defined as unscheduled removal of an endotraacheal tube (excludes tracheostomy tube) either related to the accidental dislodgement due to care processes or due to patient extubating self.  
**** Bipap is only used in non-ventilated, extubated patients. 
**** DC BIPAP will be defined as OFF bipap for >=24 hrs
**** Home bipap or cpap is included in this study. 
* If the device is '''removed or stopped for more than one day''' and then a new device is used, a new set of entries is required to get an accurate duration for the device.


*Trach_IN - date & time
*Each item must have a partner:  For example if central line "in" is an option, then central line "out" must be entered.  If it remains in after discharge then the box is ticked in the "out" option.  "Start" items must be paired with "stop" items and "in" items must be paired with "out" items.  When you send, if the paired items are not entered for your completed pts, you will get a list of errors when you check your pre-send checker. 
*Trach_OUT - date & time
** Another example: when both "ETT in and Vent start" are simultaneous , then decided to stop the vent but kept the ETT in and then the ETT was removed later on another date, only 3 date_times should be recorded namely 1) ETT_in & Vent_start, 2) Zvent_stop, 3) ZETT_out. Despite only having 3 dates, the partners are satisfied (eg. ETT_in & vent_start will be partner for both Zvent_stop and ZETT_out).
*** Example of Valid pairings
****"ETT in and Vent start" and "ETT out and Vent stop"
****"ETT in and Vent start" and "Zvent_stop" followed by "ZETT_out"
****"ETT in" and "ETT out"
****"ZVent start" and "ZVent stop"
*** Example of NOT valid pairings
****"ETT in and Vent start" and "ZETT_out" followed by "ZVent_stop" if without trach
****"ETT in and Vent start" and "ZETT_out" only
****"ETT in and Vent start" and "ZVent_stop" only
****"ZETT in" and "ETT out and Vent stop"
****"ZETT in" and "ZVent_stop"
****"ZVent start" and "ETT out and Vent stop"
****"ZVent start" and "ZETT out"


*Vent start_IN - date & time
*Call me if you are unclear about these rules and I will try to clarify.  You can always Page me and I will respond ASAP.  Pager 932-0653 if you need help on the spot with this.  --[[User:LKolesar|LKolesar]] 07:06, 20 October 2011 (CDT)
*Vent stop_OUT - date & time
**DC Vent will be defined as OFF the ventilator for >=48 hrs


*BIPAP/CPAP start_IN - date & time
Further instructions will follow as we start working with this tool. Anyone can start trialing this any time because Tina has put it on the laptops.  This only applies to critical care collectors.  Feedback is welcomed as you start collecting this information.  The actual project will start Jan 1, 2012 but you are expected to work with it on a trial basis somewhat before that date so that you are familiar with it and all the glitches can be worked out.
*BIPAP/CPAP stop_OUT - date & time
**DC BIPAP will be defined as OFF the ventilator for >=24 hrs


==Instructions for collecting==
*Can I assume that when a patient dies with any of the devices in, that we show them as if out when discharged?--[[User:Jpeterson|Jpeterson]] 09:51, 1 November 2011 (CDT)
*For each option you need to click on "edit" to bring up the full page, on this page you will see a box to tick off if the "in" item (device) is present on admission.  For the "out" item the option to tick will say "present on discharge". 
*Yes, that is correct.
*The focus is to determine number of days with each device but if the device is present on admission it is not necessary to try to find prior date and time for this.  If the device is removed or stopped for a few days and then a new device is used, this new date and time needs to be documented, ensuring that the original date and time of removal or stop is indicated.
*You can either tick the box (present at discharge) if the devices were still left in when the pt went to the morgue, OR you can just put all devices out at the time of deathJulie knows at death that all devices are stopped. --[[User:LKolesar|LKolesar]] 11:09, 25 November 2011 (CST)
*A separate item is unplanned extubations.  Even when this occurs, be sure to also indicate ETT out date and time even if it is the same as the unplanned.  This is necessary because the pt may be re-intubated and then the ETT out will not be completed at the same date and time because the  ETT days will continue.   
*Home bipap or cpap is included in this study.
 
Further instructions will follow as we start working with this tool. Anyone can start trialing this any time because Tina has put it on the laptops.  This only applies to critical care collectors.  Feedback is welcomed as you start collecting this information.  The actual project will start Jan 1, 2011 but you are encouraged to work with it on a trial basis somewhat before that date so that you are familiar with it and all the glitches can be worked out.


==Start Date==
==Start Date==
Line 70: Line 100:


==Stop Date==
==Stop Date==
Discontinued December 5, 2011


==Analysis==
The [[Statistician]] will derive the intermediate variables:
*Invasive Mechanical Ventilator Days:  The number of MV patients in the ICU at approximately the same time every day


==Analysis==
*Non-Invasive MV days: The number of Non-invasive MV patients in the ICU at approximately the same time every day
Will be handled by [[Statistician]]
 
# number of central line days between [[Central Line Related Blood stream Infection (CLR-BSI)]]
*Total MV days: The number of MV (invasive and non-invasive ) patients in the ICU at approximately the same time every day
# number of Vent days between unplanned extubations
 
# number of Vent days between [[VAP]]
*Mechanical ventilation time: The duration of MV (both Non-invasive and invasive) per person
 
*CL days: The number of patients with a central line in the ICU at approximately the same time every day
 
*Number of Unplanned extubations
 
*Number of Re-intubations
 
The [[Statistician]] will perform the analysis of the following Quality Indicators:
 
*Ventilated Patient Flow (VPF) is a measurement of the proportion of ICU patients having been ventilated at any time during their ICU stay.
 
*Ventilator Utilization Ratio (VUR) is a measure of  the proportion of ICU days being spent on mechanical ventilation.
 
*Ventilator Associated Pneumonia (VAP) reported as a rate of VAP per 1000 mechanical ventilation days.  Also reported as the number of mechanical ventilator days in between VAP cases. 
 
*Unplanned extubation is the unscheduled removal of an artificial airway (endotracheal or tracheostomy tube) due to accidental dislodgement or patient self extubation. The patient need not be ventilated at the time of the event (eg. tracheal collar).
 
*Failed extubation rate is the requirement for re-intubation within 48 hours of extubation during the same ICU admission.  It is expressed as a rate per 1000 MV days.  It is also expressed as a percentage of all planned extubations. 
 
*Time on mechanical ventilator is the median time on the ventilator for all ventilated patients.  This is calculated monthly. 


*Central line associated blood-stream infection is the number of CLA-BSI per 1000 central line days.  This is also reported as the number of CL days in between CLA-BSI.


*Number of PICC being used in our units compared to central lines as approximately half of the CLA-BSI in 2010 were associated with PICC.


--[[User:TOstryzniuk|TOstryzniuk]] 18:02, 31 August 2011 (CDT)
[[Category: QA]]
[[Category: QA]]
[[Category:All Projects]]

Latest revision as of 15:21, 2021 June 15

Projects
Active?: legacy
Program: CC
Requestor: Unknown/legacy
Collection start: 2011-01-01
Collection end: 2011-12-05

Legacy only, see below for details







DeviseUse Study (this is the spelling of the study in our program and on the wiki)

Purpose

Monitor resource allocation and monitor complication rates related to length of ICU medical device use. (VAP, Central Line Related Blood stream Infection (CLR-BSI), unplanned extubations) to improve patient quality of patient care in critical care.

Who

Information to be collected from charts daily by Regional Database Team - Critical Care areas.

  • Monitoring being done by the Critical Care QI Team. Members of the CCQI team will also provide ongoing support and feedback for issue related to collection of this data from chart.
  • Only the ICU's in the city will be collecting this information. No device use information will be collected at the CCU's at STB and HSC or the Cardiac ICU at STB. IICU will collect this data.
  • Laura Kolesar will be the lead data collector who will work with CCQI team, Statistician & Tina Tenbergen on matters related to this project.

Where

Data will be collected in all ICUs in the region.

Data will be stored de-identified in L TmpV2 in the output folder on the Regional Server.

How often data is sent

  • Information sent each week with sending to L TmpV2 even though patient files is not complete.

Instructions for collecting

  • Exact time is not necessary, approximate time is OK.
  • The focus is to determine number of days with each device while in the unit,but also we are tracking the number of times intubated during a stay. So all extubations and intubations need to be put in the list even if it is done the same day.
  • For each of the following devices, enter an in and out record or start and stop record for each device present:
    • on "in" or "start" record, tick off "present on admission" instead of entering a date if the device is present on admission. The same goes for if the device is "present on discharge" You need to put the "out" or "stop" option and then tick off "present on discharge". To view this option, click on the "edit" button.
      • if date is absent and the box is ticked , the Statistician will use the Admit Date/Time as the "in" or "start" date
      • if date is present and is different from Admit Date/Time, there is no need to tick the box.
    • on "out" or "stop" record, tick off "present on discharge" instead of entering a date if the device is present on discharge
      • if date is absent and the box is ticked , the Statistician will use the Discharge Date/Time as the "out" or "stop" date
      • if date is present and is different from Discharge Date/Time, there is no need to tick the box.
    • devices:
      • Central line (first in and last out)
        • doesn't matter how many central lines a patient has at the same time (hint: if helps to keep track by writing in the note section which line it is for your own benefit.)
      • PICC line when in and when out.
      • ETT in & vent start, use this option if both are simultaneous (if not use individual options which have a "Z" in front)
      • ETT out & vent stop, use this option if both are simultaneous (if not use individual options which have a "Z" in front)
      • zETT in and out is used if done independently of vent.
      • zVent stop and start is used if done independently of ETT in and out.
        • If an unplanned extubation occurs enter a record for this in addition to documenting the ETT out/vent stop records
      • Trach when in and when out.
      • BIPAP/CPAP start and stop Changed title to BI/CPAP start/stop to make shorter
        • Bipap is only used in non-ventilated, extubated patients.
        • DC BIPAP will be defined as OFF bipap for >=24 hrs
        • Home bipap or cpap is included in this study.
  • If the device is removed or stopped for more than one day and then a new device is used, a new set of entries is required to get an accurate duration for the device.
  • Each item must have a partner: For example if central line "in" is an option, then central line "out" must be entered. If it remains in after discharge then the box is ticked in the "out" option. "Start" items must be paired with "stop" items and "in" items must be paired with "out" items. When you send, if the paired items are not entered for your completed pts, you will get a list of errors when you check your pre-send checker.
    • Another example: when both "ETT in and Vent start" are simultaneous , then decided to stop the vent but kept the ETT in and then the ETT was removed later on another date, only 3 date_times should be recorded namely 1) ETT_in & Vent_start, 2) Zvent_stop, 3) ZETT_out. Despite only having 3 dates, the partners are satisfied (eg. ETT_in & vent_start will be partner for both Zvent_stop and ZETT_out).
      • Example of Valid pairings
        • "ETT in and Vent start" and "ETT out and Vent stop"
        • "ETT in and Vent start" and "Zvent_stop" followed by "ZETT_out"
        • "ETT in" and "ETT out"
        • "ZVent start" and "ZVent stop"
      • Example of NOT valid pairings
        • "ETT in and Vent start" and "ZETT_out" followed by "ZVent_stop" if without trach
        • "ETT in and Vent start" and "ZETT_out" only
        • "ETT in and Vent start" and "ZVent_stop" only
        • "ZETT in" and "ETT out and Vent stop"
        • "ZETT in" and "ZVent_stop"
        • "ZVent start" and "ETT out and Vent stop"
        • "ZVent start" and "ZETT out"
  • Call me if you are unclear about these rules and I will try to clarify. You can always Page me and I will respond ASAP. Pager 932-0653 if you need help on the spot with this. --LKolesar 07:06, 20 October 2011 (CDT)

Further instructions will follow as we start working with this tool. Anyone can start trialing this any time because Tina has put it on the laptops. This only applies to critical care collectors. Feedback is welcomed as you start collecting this information. The actual project will start Jan 1, 2012 but you are expected to work with it on a trial basis somewhat before that date so that you are familiar with it and all the glitches can be worked out.

  • Can I assume that when a patient dies with any of the devices in, that we show them as if out when discharged?--Jpeterson 09:51, 1 November 2011 (CDT)
  • Yes, that is correct.
  • You can either tick the box (present at discharge) if the devices were still left in when the pt went to the morgue, OR you can just put all devices out at the time of death. Julie knows at death that all devices are stopped. --LKolesar 11:09, 25 November 2011 (CST)

Start Date

Testing

Anyone who wishes to test this is welcome to do so. Start of testing Oct 1.11. Document any difficulties encountered. Be sure to at least try this out prior to the start date to ensure familiarity.

Data collection

The actual start date of the project will be Jan 1, 2011.

Stop Date

Discontinued December 5, 2011

Analysis

The Statistician will derive the intermediate variables:

  • Invasive Mechanical Ventilator Days: The number of MV patients in the ICU at approximately the same time every day
  • Non-Invasive MV days: The number of Non-invasive MV patients in the ICU at approximately the same time every day
  • Total MV days: The number of MV (invasive and non-invasive ) patients in the ICU at approximately the same time every day
  • Mechanical ventilation time: The duration of MV (both Non-invasive and invasive) per person
  • CL days: The number of patients with a central line in the ICU at approximately the same time every day
  • Number of Unplanned extubations
  • Number of Re-intubations


The Statistician will perform the analysis of the following Quality Indicators:

  • Ventilated Patient Flow (VPF) is a measurement of the proportion of ICU patients having been ventilated at any time during their ICU stay.
  • Ventilator Utilization Ratio (VUR) is a measure of the proportion of ICU days being spent on mechanical ventilation.
  • Ventilator Associated Pneumonia (VAP) reported as a rate of VAP per 1000 mechanical ventilation days. Also reported as the number of mechanical ventilator days in between VAP cases.
  • Unplanned extubation is the unscheduled removal of an artificial airway (endotracheal or tracheostomy tube) due to accidental dislodgement or patient self extubation. The patient need not be ventilated at the time of the event (eg. tracheal collar).
  • Failed extubation rate is the requirement for re-intubation within 48 hours of extubation during the same ICU admission. It is expressed as a rate per 1000 MV days. It is also expressed as a percentage of all planned extubations.
  • Time on mechanical ventilator is the median time on the ventilator for all ventilated patients. This is calculated monthly.
  • Central line associated blood-stream infection is the number of CLA-BSI per 1000 central line days. This is also reported as the number of CL days in between CLA-BSI.
  • Number of PICC being used in our units compared to central lines as approximately half of the CLA-BSI in 2010 were associated with PICC.