Special Software installed

SAS

  • looks like this can be run with the standard Shared Health install now
  • Yearly license is made thru University of Manitoba. Contact Person Melanie Hamel. See details in shared folder S:\MED\MED_CCMED\Julie\Software_License_Renewal\SAS Renewal.
  • The Statistician Julie Mojica is also a staff of University of Manitoba.

SQCPack

  • Started Date : 2012-2021 (Chart Runner), 2021 SQC Pack 8
  • Yearly license is made thru PQ Systems. Contact person is Marilou Brown. See details in shared folder S:\MED\MED_CCMED\Julie\Software_License_Renewal\CharRunner Renewal
  • Chart Runner Lean stopped its upgrading 2021 and has been replaced by SQC pack in 2021.
  • Two licenses for the Statistician of CCMDB Julie Mojica and Dr. Kendiss Olafson from the Outcomes Improvement Team
    • Starting 2023, only one license for Julie Mojica is being paid by the Critical Care Program. The other license is being paied by Dr. Kendiss Olafson.
  • Have been used for Canada Vital Sign Monitor until 2014 and Critical Care Program Quality Indicator Report up to present

Legacy Issue in Chart Runner Lean Software

Microsoft Access Runtimes to deal with bit-wise and Office Version incompatibility

With Office/Access 2019 installed,

CHARTRunner encountered an issue while displaying your chart. The chart settings need to be edited. 
The 'Microsoft.ACE.OLEDB.12.0' provider is not registered on the local machine.
  • #SAS 9.4 gives the following error:
ERROR: Connect: Class not registered 
ERROR: Error in the LIBNAME statement.

The solution is for someone with admin rights to install the following, in that order:

  1. 2013 Runtime - use the 64-bit one
    • regular install
  2. 2010 Runtime - use the 32-bit one, not the 64-bit one
    • run this from the command line with /passive parameter, ie AccessRuntime.exe /passive to avoid bitwise incompatibility error

2010 fixes CHARTRunner, 2013 SAS, so if only one is still required only install that runtime.