Check APACHE physiological variable high low
| Data Integrity Checks | |
| Summary: | an APACHE physiological variable is extremely high or low |
| Related: | [[AaDO2, AP Dias BP Field, AP Sys BP Field, Creatinine (APACHE), FiO2, HCT, Hemat, HR, K, Na,PCO2, PH, PO2, RR, Serum CO2, Temperature, WBC]] |
| Firmness: | hard check and soft check |
| Timing: | |
| App: | CCMDB.mdb |
| Coding: | functions validate_x, function Min_Max_Checker |
| Uses L Problem table: | not relevant for this app |
| Status: | implemented |
| Implementation Date: | 2008-01-01 |
| Backlogged: | true |
Implementation
The various validate_x functions in CCMDB.mdb call the function Min_Max_Checker with parameters for absolute and warning thresholds.
This was implemented with the first version of CCMDB, so not clear now what the date was.