AP Sys BP Field: Difference between revisions

From CCMDB Wiki
Jump to navigation Jump to search
mNo edit summary
mNo edit summary
 
(16 intermediate revisions by 3 users not shown)
Line 1: Line 1:
The '''AP Sys [[BP]]''' data input field records '''SYSTOLIC''' blood pressure value.
{{Data element
|field_name=Ap_APSysBP
|CCMDB_label=APSysBP
|CCMDB_tab=Apache
|in_table=L Log table
|data_type=number
|datafield_length=single
|program_collecting=CC
|created_raw=Raw
|data_element_sort_index=59
|element_description=Ap_SysBP is the systolic blood pressure.
}}
== Different instructions for ICU and Medicine ==
The details of collection for ICU and medicine are different. For the timing and which value to use, see:
* for ICU: [[Mean BP]]
* for medicine: [[ALERT Scale]]


If a value for this is not available, follow the [[Apache II General Collection Guidelines#Missing Values Rule for APACHE II | missing value rule]].
{{APACHE physiological variable
|AP phys name= Systolic Blood Pressure
|AP phys unit= mmHG
|AP phys absMax= 360
|AP phys warnMax= 243
|AP 0= as per [[Mean BP]]
|AP phys warnMin= 49
|AP phys absMin= 25
}}


==Medicine==
== Data use ==
Apache Systolic [[BP]] is used for the '''[[:Category: MOST | MOST]]''' score.
Apache Systolic [[BP]] is used for the '''[[ALERT Scale]]''' score.
*for MOST - Value selected is one that is "'''closest to the time'''" just prior to when the medicine service physician "accepts" the patient to the medicine service.


==Critical Care==
== Data Integrity Checks ==
*It is also one of the values used to calculate the [[Mean BP | Mean BP]] for [[:category:APACHE II|APACHE II]].
{{Data Integrity Check List}}
**for selecting [[BP]] values for [[APACHE II]], please refer to: [[Mean BP | Mean BP]]
==Blood Pressure when on IAPB (intra aortic balloon pump)==
*If on IABP, use peripheral arterial BP, NOT aortic pressure.  We want the worst value in the 1st 24 hrs in ICU, so if possible it would be PRE IABP BP.  If pt comes out of OR with IABP use peripheral arterial BP not aortic BP.--[[User:Agarland|Dr. Allan Garland]], Dr. Bojan Paunovic, --[[User:TOstryzniuk|TOstryzniuk]] 16:28, 31 January 2011 (CST)


== Data Integrity Rules ==
The AP Sys [[BP]] must be >=25 And <=360.


[[Category:APACHE II Physiological Variables]]
[[Category: Blood Pressure-APACHE]]
[[Category: Blood Pressure-APACHE]]
[[Category: MOST Score Elements]]
[[Category: ALERT Scale Elements]]
[[Category: Data Integrity Rules]]

Latest revision as of 01:34, 2019 January 3

Data Element (edit)
Field Name: Ap_APSysBP
CCMDB Label: APSysBP
CCMDB tab: Apache
Table: L Log table
Data type: number
Length: single
Program: CC
Created/Raw: Raw
Start Date: 1988-07-11
End Date: 2300-01-01
Sort Index: 59

Ap_SysBP is the systolic blood pressure.

  • SMW

Legacy implementation right in the table

  • Cargo


  • Categories
  • Forms


Different instructions for ICU and Medicine

The details of collection for ICU and medicine are different. For the timing and which value to use, see:


Apache Physiological Variable
variable name Systolic Blood Pressure
unit mmHG
absolute max allowed 360
warning max 243
high score 4
high score 3
high score 2
high score 1
score 0 as per Mean BP
low score 1
low score 2
low score 3
low score 4
AP phys warnMin 49
AP phys absMin 25

APACHE Score

This value is used to generate the APACHE Score.

Collecting Apache physiological variables

There are some specific rules to follow in choosing which one of several lab results to collect.

See APACHE physiological variable collection for details.

Cross Chcks

Rules described in APACHE_physiological_variable_collection#Exceptionally_high_or_low_values are implemented by Check APACHE physiological variable high low.

Data use

Apache Systolic BP is used for the ALERT Scale score.

Data Integrity Checks

Data Integrity Checks (automatic list)

 AppStatus
Check APACHE physiological variable high lowCCMDB.accdbimplemented