Used in aggregate form as "per location" and/or "per timeframe", e.g. by month/quarter/year x Ward/Unit x Hospital


==QI domain==
==QI domain==
Line 27: Line 28:
===Frequency===
===Frequency===
* Daily occupancy of patients who stayed in ICU   
* Daily occupancy of patients who stayed in ICU   
* Daily recording of dates of patient being on invasive mechanical ventilation
* Daily recording of dates of patient being on invasive mechanical ventilation '''any time'''
* Total occupancy in terms of  patient days are calculated  and reported on a monthly, quarterly or yearly basis based on the daily data.
* Total occupancy in terms of  patient days are calculated  and reported on a monthly, quarterly or yearly basis based on the daily data.
* Total number of ventilated days are calculated and reported on a monthly, quarterly or yearly basis based on the daily data.
* Total number of ventilated days are calculated and reported on a monthly, quarterly or yearly basis based on the daily data.
* Time Reference is calendar month, quarter or year.
* Time Reference is '''calendar''' month, quarter or year.
 
==Definition and Derivation==
==Definition and Derivation==
===Numerator===
===Numerator===
Line 45: Line 47:


==Data Sources==
==Data Sources==
*Daily data for Invasive are taken on [[TISS28]] element {{TISS w Nr | Invasive Mechanical Ventilation (TISS Item)}}.  The TISS form is being marked daily by ICU bed side nurses and quality checked by the Database Data Collectors.
*Daily data for Invasive are taken on [[TISS28]] element {{TISS w Nr | Invasive Mechanical Ventilation (TISS Item)}}.  The TISS form is being marked daily by ICU bed side nurses and quality checked by the Database Data Collectors. Starting Oct 1, 2020, this [[TISS28]] element is collected and entered as CCI procedures by the Database Data Collectors.  
*Daily occupancy per day are derived from [[Accept DtTm]] or [[Arrive DtTm]] and [[Dispo DtTm]].
*Daily occupancy per day are derived from [[Admit DtTm]] and [[Dispo DtTm]].


==SAS Program==
==SAS Program==
Part of X:\Julie\SAS_CFE\CC_reports\ChartReport\prepCCChart.sas
*S:\MED\MED_CCMED\Julie\SAS_CFE\CFE_macros\Prep_CCI_TISS.sas
*Part of X:\Julie\SAS_CFE\CC_reports\ChartReport\prepCCChart.sas
 
==Report Users==
==Report Users==
*Critical Care Directors and Site  Managers
*Critical Care Directors and Site  Managers
Line 60: Line 64:
[[Category:TISS28]]
[[Category:TISS28]]
[[Category:Admit/Discharge]]
[[Category:Admit/Discharge]]
[[Category: Data Use]]
[[Category: Reporting]]
[[Category: Statistical Analysis]]

Latest revision as of 16:46, 2022 April 21

Ventilator Utilization Ratio (VUR) is proportion of ICU days being spent on invasive mechanical ventilation.

Indicators
Indicator: Ventilator Utilization Ratio (VUR)
Created/Raw: Created
Program: Critical Care
Start Date: Jan 1 2013
End Date:
Reports: Critical Care Program Quality Indicator Report, Directors Quarterly and Annual Report (Critical Care)


  • Cargo


  • SMW:
  • Categories
  • Default form:

Used in aggregate form as "per location" and/or "per timeframe", e.g. by month/quarter/year x Ward/Unit x Hospital

QI domain

  • Efficient

Reported as

Ventilation days / Total Patient days in percent (%)

Significance

VUR is a surrogate marker of multiple interrelated factors: ICU patients characteristics (acuity, comorbidity, premorbid functional status), structural and process-related aspects of ICU care (staffing ratios, staff expertise, processes for effective ventilator), hospital factors (presence of step-down unit, factors affecting patient flow).

Sampling Plan / Procedure

Inclusion Criteria

Exclusion Criteria

  • Exclude non-invasive ventilation.

Frequency

  • Daily occupancy of patients who stayed in ICU
  • Daily recording of dates of patient being on invasive mechanical ventilation any time
  • Total occupancy in terms of patient days are calculated and reported on a monthly, quarterly or yearly basis based on the daily data.
  • Total number of ventilated days are calculated and reported on a monthly, quarterly or yearly basis based on the daily data.
  • Time Reference is calendar month, quarter or year.

Definition and Derivation

Numerator

Num = Total Invasive Mechanical Vent Days in a calendar period

Denominator

Denom =Total Patient Days on the same period as the numerator

Formula

VUR = Num / Denom * 100

Example

  • Time Reference: Calendar Dates from Jan 1, 2017 to March 31, 2017
  • Total days patients are on invasive ventilator = 830
  • Total patient days from Jan 1, 2017 to March 31, 2017 at HSC MICU = 1103.7
  • VUR (%) = 830 / 1103.7 = 75.2%

Data Sources

  • Daily data for Invasive are taken on TISS28 element T18 - Invasive Mechanical Ventilation (TISS Item). The TISS form is being marked daily by ICU bed side nurses and quality checked by the Database Data Collectors. Starting Oct 1, 2020, this TISS28 element is collected and entered as CCI procedures by the Database Data Collectors.
  • Daily occupancy per day are derived from Admit DtTm and Dispo DtTm.

SAS Program

  • S:\MED\MED_CCMED\Julie\SAS_CFE\CFE_macros\Prep_CCI_TISS.sas
  • Part of X:\Julie\SAS_CFE\CC_reports\ChartReport\prepCCChart.sas

Report Users

  • Critical Care Directors and Site Managers
  • Critical Care Quality Improvement Team (QIT)

Related articles

Related articles: