TISS28 Form Scanning: Difference between revisions

From CCMDB Wiki
Jump to navigation Jump to search
Line 61: Line 61:
# Double-click on the '''Teleform Verifier''' shortcut on the desktop (red checkmark on keypad icon)
# Double-click on the '''Teleform Verifier''' shortcut on the desktop (red checkmark on keypad icon)
# click on the line with the latest batch number, status column should say "Ready for Correction", Line will be highlighted
# click on the line with the latest batch number, status column should say "Ready for Correction", Line will be highlighted
# click the '''Process''' button on the right,  Screen will then show the TISS form that was scanned
# Double click on the highlighted line
# correct all entries the program presents
# correct all entries the program presents
# when dialog box asks "save corrections to results file" click OK,  When done the forms in that batch, the screen will show "batch ready to be committed"
# when dialog box asks "save corrections to results file" click OK,  When done the forms in that batch, the screen will show "batch ready to be committed"

Revision as of 15:48, 2016 June 16

The purpose of this article is to outline the process of scanning TISS28 paper forms, verifying the data in Teleform and committing the data to the TISS28 MS Access database.

These instructions are applicable to the following:

  • Teleform version 10.9 installed in a PC running Windows 7
  • Scanning to a network share from a multifunction printer/scanner

For additional information see this article: Teleform

Scanning problems

  • 2016_April_15: Since Dec 2015, Pagasa is using the glass on scanner rather than document feed particularly for TISS most of the days filled. (having to flip over pages manually one by one to do this). This takes more time to scan TISS forms however, this produces better quality of scans, they are not crooked, and she has less problems with Teleform reading crooked scans and then having to rescan. Perhaps we can obtain different fax/printer/scanner, find one with more reliable document feed suitable? - Trish Ostryzniuk 16:52, 2016 April 15 (CDT)
    • We discussed that Pagasa would start by contacting the helpdesk about this to confirm the scanner is working as well as it can.
      • 2016_April_19: eHealth came by. They will contact vendor to look at and if document feed roller needs to be replaced.
      • 2016_April_19: vendor came by office today and replaced tray 1 pick up tires and ADF roller. This did not resolve the crooked scans. As it was tested after replacing these parts. Vendor will order document feed part and replace when it comes in. Pagasa will report if scanning improved when document feed part replaced.
        • Feedback from repair person is that this type of scanner/printer/fax, is not suitable for the volume of scanning we are doing.
        • If that does not improve the situation, we can "test the model" Accuro uses, would need to coordinate with Kym Morris.
        • Note; Pagasa's feedback is that this solution is nto suitable to workflow, as she will be running in and out of office often, even just to rescan a form. it would be very disruptive to her other daily Task that she must do.
  • Also asked Pagasa to show Tina next time a form is not scanned straight so we can check on the interface in Teleform to see if there are different ways to use.
  • Finally, we have a new version of Teleform that needs to be installed, maybe it will cope better with bad scans. Ttenbergen 11:26, 2016 April 18 (CDT)

Start Date

January 1, 2013

  • TISS28 data for the entire LOS is scanned and stored in new repository TISS28_Data.mdb. This form has 7 days per page.

Prior to starting scanning

  • Review each TISS and black blob those that you can tell verifier will not pick up well.
  • page numbers don't fuss, does not matter what page number is the form. Use 001

TISS data grouping in the TISS28 Data.mdb

  • TISS28 Data.mdb stores TISS by groups and date order.
    • there is an issue that for some TISS, they are not being grouped in this mdb. Not sure why. Sheila Rusnak has pointed this out several times. When searching in this mdb in order to find what is already scanned. You may have to press find NEXT, if maybe one page is not being grouped as it should be with other site serial Location.
      • when location is changed after importing scanned forms into TISS28 Data.mdb, we find that when looking in this mdb, the TISS will no longer be GROUPED together for location and consecutive dates. PTorres 12:03, 2015 October 2 (CDT)
        • Not sure if this can be fixed. No right now.
          • the next guy must know that because location is common error and does not get picked up and fixed until after importing in TISS28.Data.mdb, will have to click "next" in the mdb to see if addition forms is there.
            • This is when the location is changed in this mdb.

Scanning forms

Special NOTE: HSC TISS forms Locations:

  • MICa, MICb, MICd
  • SICa, SICb, SICd
  • IICa, IICb, IICd
  • CCUa, CCUb, CCUd

On the scanner:

  1. put forms into scanner face up
  2. on scanner interface, click "Scan to Network"
  3. click "Scan to Network" a second time
  4. click "change..."
    • under "sides(duplex)" choose "2 sided"
    • under "Scan As" choose TIFF
    • under "Advanced options" Click Darkness
  5. click "Scan it" button

When scanning done, it will say "scan successful"

Teleform ScanStation

On the Scanner PC:

  1. Double-click on the Teleform Reader shortcut on the desktop (eyeglasses icon)

Verifying

'Scanning Folder' should always only have one batch in it as a .TIF file

  1. Double-click on the Teleform Verifier shortcut on the desktop (red checkmark on keypad icon)
  2. click on the line with the latest batch number, status column should say "Ready for Correction", Line will be highlighted
  3. Double click on the highlighted line
  4. correct all entries the program presents
  5. when dialog box asks "save corrections to results file" click OK, When done the forms in that batch, the screen will show "batch ready to be committed"
  6. right-click the batch and click "Commit"; say "Yes" to "Commit batch data?", When batch is committed, screen will show "batch is complete"

Importing TISS

  1. Open the TISS 28 Database (Access icon), Enter password
  2. Click Import TISS Data
  3. A message will come out telling the numbers of TISS forms imported successfully
  4. It will show up TISS serial number imported and you can check against the TISS forms

Update TISS28.mdb

  1. Once you finished importing all the tiss
  2. Open the TISS28.mdb
  3. Click Prepared Report
  4. Click the Data by Patient and Date View and then click "Run" it takes 3 minutes to run
  5. After running the Data by Patient and Data View Click Count of Tiss items

Scan batch number recording & temporary form stacking

  • After you import a group of tiss, put the batch number only on the first form then stack it beside the work station.

Disposing of the tiss forms

  • We keep 3 months of tiss form stack then we confidential waste the oldest tiss group stack.

Error Checker Run by SAS

Template:Discussion

  • Are there special steps how to review the data in each of these excel outputs by the processor?
  • How should this be run and reviewed, weekly or few weeks before quarterly report?
  • What is the process if errors are found?

By running SAS checker, 3 files are outputted in excel format:

  • TISS28Errors (with date run)-report contains the extra TISS days and the missing TISS days
  • TISS28Pending (with date run)- use by Julie, so she can quickly see last date up to which there is complete data in TISS28.data.mdb
  • Tiss28Reminder (with date run)-Started March 2016 - lists record status of all complete and incomplete with missing TISS, 14 days prior to current date.
  1. To run this program use the laptop or Julie's computer with SAS program (Template:Discussion Pagasa has password - needs to be put on excel main office use only password list located on: M drive)
  2. Double click on the SAS 9.3 a message will pop up click "close"
  3. Go to File then Open program
  4. Go to My Computer, find: X drive
  5. On X drive double click on PAGASA's folder
  6. Double click on TISS28 folder
  7. Double click on "chkTiss28CD_ver6" and you will see the program
  8. You must change the date on "version=ddmmmyy" to the current date
  9. Change also the date on "enddate=ddmmmyyyy" to the currecnt date
  10. Then click run "picture of a man walking" . Takes about 5 minutes to run.
  11. Click SAVE
  12. Click (X) it will ask you if you want to replace the previous output click "YES"
  13. Will ask you if sure to leave SAS click "YES"

Steps for Processing of TISS errors Error

TISS Error Output from SAS is located in\\Hsc1msfp0001\med_ccmed\PAGASA\TISS28

  1. Open the Tiss28Errors_01Oct2015_b_rtf, to see the output error.
  2. Copy the list in excell so you can manipulate the filter.
  3. Error on: Date,Location, Missing day or Extra day, checked the "EPR" to see patient visit info.
  4. If after investigation you cannot reconcile the error that is the only time you ask the collector by email or by phone.

To navigate in EPR get the chart number or you can search by name also.

  • Click File then Find Patient then enter the chart number on the ID and the site location on the IDlocation then Search.
  • Note for Stb you have to add "0" then the chart number then Search, for other sites you dont need to do that.
  • Once you get patient name highlighted it then click Shows visits.
  • Click the date you want to see the admission then click "OK".
  • Then click to Registration then Visit Location then Location History will pop up the admission of the patient.
  • It appear that: Sometimes TISS form is printed out other times not. Sometimes a for is filled out for missing day and scanned in, other times not and extra day manually added to TISS28 Data.mdb.

Disposal of TISS forms

Data processor keeps scanned forms at workstation. Approx. 4 months of forms are kept, then oldest is disposed end of 4th month as confidential waste.

Filing of TISS28 forms

Being stored as electronic and paper form.

Electronic Images

The scanned images are stored on the following network share:

  • \\hsc1msfp0001\med_ccmed\TISS28\ExportData\Images

This share has a sub-folder for each batch that has been processed. Currently there are two types of batch numbers. Any folder in this directory with the suffix: "_old" is pre-Windows7. The Windows 7 upgrade involved upgrading Teleform. The Teleform upgrade caused a reset to the sequence of batch numbers. All code in the TISS28 DB has been updated and is fully operational for this change. All batches going forward are simply numeric.

Locating Images

There are two methods that can be used to locate an image. Simply by serial number - this is the serial number entered on the form at the hospital. There are duplicate serial numbers and this method will return all potential matches but will show the following information:

  • Site
  • Unit
  • Serial
  • Batch No
  • First Date
  • Image File - with the option to open and view the file (click the button next to this field on the form)

An alternate method is to search based on a combination of: Site + Unit + Serial

This method reports the same data outlined above.

Backups of the Forms

The forms are backed up from the scanner PC to X:\TISS28\ExportData\Images


Supplementary Information

Other things to resolve with data processing

  • site STB ICMS & STB ICCS - will want a PROGRAM & not a data collector to correct the location name on form for STB
  • if STB_ICMS convert to STB_MICU
  • if STB_ICCS convert to STB_CICU

Is this an outstanding problem? If so, please add to Change Priorities. Ttenbergen 19:32, 2014 April 30 (CDT)Trish Ostryzniuk 18:33, 2015 March 13 (CDT)Template:Potential Change

Trouble shooting of the tiss 28 forms

  • If encountered problem like this message "the instruction at 0X3894ffo"
  • Go to X:\Tiss28
  • Then open the ExportData with 2 folders 1) Images 2)Archives.
  • Archive is the csv data of the batch you scanned and verified after you commited the batch in the Teleform it goes to the Archive folder.
  • Sometimes the error messages shows up when commitng so I dont import the batch and check what is the problem.
  • Some of the common error are if the Location or the Site is incorrect it just give you this error message"the instruction at 0X3894ffo
  • Go To Access database into the Edit Tiss data click find and enter the serial number.

Original transition from TISS76 to TISS28

  • Example: If patient has one page already completed in December and a NEW TISS form is started Jan 1, is this page number 2?
    • as addressed in email over holidays, doesn't matter what number is used since the field is not imported. Ttenbergen 11:10, 2013 January 7 (EST)

January 1, 2013 - New TISS28 forms; we will scan all pages for entire patients LOS in ICU. New form will have 7 days per form. TISS28 data will NOT be uploaded to master TMSX (Critical Care) database. See TISS28_data_specifications#Location_of_data about where thsi will be stored.