Query s tmp QAInf tmp no dx: Difference between revisions
Jump to navigation
Jump to search
Ttenbergen (talk | contribs) mNo edit summary |
Ttenbergen (talk | contribs) mNo edit summary |
||
Line 1: | Line 1: | ||
{{Data Integrity Check | {{Data Integrity Check | ||
| DIC_summary = If "QAInf" entry is present in [[L_TmpV2]] then | |DIC_summary=If "QAInf" entry is present in [[L_TmpV2]] then | ||
* program must be "CC" | * program must be "CC" | ||
* the '''corresponding''' diagnosis must exist | * the '''corresponding''' diagnosis must exist | ||
| DIC_related_concepts = QA Infection; QA Infection CLI; QA Infection VAP; Iatrogenic, infection, central venous catheter-related bloodstream infection (CVC-BSI, CLI); Pneumonia, ventilator-associated (VAP) | |DIC_related_concepts=QA Infection; QA Infection CLI; QA Infection VAP; Iatrogenic, infection, central venous catheter-related bloodstream infection (CVC-BSI, CLI); Pneumonia, ventilator-associated (VAP) | ||
| DIC_firmness = hard check | |DIC_firmness=hard check | ||
|DIC_coding=Query s tmp QAInf dx no tmp | |||
|DIC_implementation_date=2009-12-29 | |||
| DIC_coding = Query s tmp QAInf dx no tmp | |DIC_status=ready to implement | ||
| DIC_status = ready to implement | |DIC_LProblem=No | ||
| | |DIC_app=CCMDB.mdb | ||
}} | }} | ||
Implement ICD10/CCI part | Implement ICD10/CCI part | ||
There is currently discussion whether CCI should have a Central Line entry... delaying implementation in case it changes this. | |||
Approximate implementation date, this is the first mention in a change log so it was present before. | Approximate implementation date, this is the first mention in a change log so it was present before. |
Revision as of 18:53, 6 November 2018
Data Integrity Checks | |
Summary: | If "QAInf" entry is present in L_TmpV2 then
|
Related: | QA Infection, QA Infection CLI, QA Infection VAP, Iatrogenic, infection, central venous catheter-related bloodstream infection (CVC-BSI, CLI), Pneumonia, ventilator-associated (VAP) |
Firmness: | hard check |
Timing: | always |
App: | CCMDB.mdb |
Coding: | Query s tmp QAInf dx no tmp |
Uses L Problem table: | not relevant for this app |
Status: | ready to implement |
Implementation Date: | 2009-12-29 |
Backlogged: | true |
Implement ICD10/CCI part
There is currently discussion whether CCI should have a Central Line entry... delaying implementation in case it changes this.
Approximate implementation date, this is the first mention in a change log so it was present before.
This query uses the following sub-queries:
- s_tmp_QAInf__dx