'''Teleform''' is the software used by the [[data processor]] to scan the [[TISS Form]]s before importing into the Critical Care Database repository [[TMSX]].
{{LegacyContent
*It was used to scan in [[iTISS]] forms for the Medicine Database Program [[MedTMS]]. This was stopped Dec 16.2006.
|explanation=TISS no longer collected on paper forms; [[Change to collect TISS data in CCI Picklist]]
|successor=[[Change to collect TISS data in CCI Picklist]]
|content= 


*For more information see: [[http://ltc.umanitoba.ca/wikis/ccmdb/images/5/52/Products-TeleForm.pdf Telform]] article.
'''[http://en.wikipedia.org/wiki/TeleForm Teleform]''' is a character recognition program used by the [[Data Processor]] to [[TISS28 Form Scanning | scan]] completed [[:Category:TISS|TISS]] forms before importing the data into the [[TISS28_Data.mdb]]. We use a [[Scanning to network| network scanner]] for this.


==Software==
The Teleform suite consists of a number of separate programs or modules to support the designing and processing of data collection forms.


== Hardware ==
: Version: 11x1_11117 as of 2016-06-02
* what is the scanner
: Serial: 400796
: License: TAH280-001H08-040001-H00WD7-D000RG-G77TZ6
: Product License - {D73FC1DE-8D31-4DF7-B69B-80270B194BC4}
Not sure how those licenses are different, they came from an email from Florence Wong to Tina Tenbergen 2016-03-17.


== Install media for Teleform ==
== File Locations ==
*Version 8.2?--[[User:TOstryzniuk|TOstryzniuk]] 22:18, 10 December 2008 (CST)
*Export data (from Teleform): \\ad.wrha.mb.ca\WRHA\HSC\shared\MED\MED_CCMED\TISS28\ExportData
*  
*Scanned images: \\ad.wrha.mb.ca\WRHA\HSC\shared\MED\MED_CCMED\TISS28\ExportData\Images
* who has the install media for Teleform,
* no longer valid, our contract has expired - Service account login info: M:\Passwords_mainoffice\Passwords_MainOffice_use.xlsx
* where is it,
* is it up-to date or should it be?


== Installing Teleform ==
==Sales and technical support==
<needs content>
:From: Digital Vision [mailto:teleform@att.net]
:Sent: Wednesday, February 11, 2015 10:53
:...
:Pierce Ennessy
:Digital Vision
:TeleForm@att.net


== Setting up the TISS forms for Teleform ==
US Toll Free: +1 844 526 7397
* documentation on how Teleform scanning is set up


=== Updates ===
:TeleForm has been completely transitioned to HP, Inc.
:To learn more, including instructions for first time access, please refer to the User Guide.


== Needed before de-stubbing ==
== Notes from Teleform install ==
* all the <...>s above
=== changing path or similar in teleform ===
Teleform stores its config data in files all over the place. You can use '''TeleForm Maintenance and Utility''' to do a find-replace on them and update them, e.g. when eHealth changes file shares.


=== Copying settings from old to new PC ===
* Export the current settings by opening TeleForm Maintenance and Utility. 
** Select Save snapshot
** Select the categories you want to save
** Click on the ... button to the right of Path and select the location to save the .zip file that contains the configuration files.
** To restore the configuration, open TeleForm Maintenance and Utility on the new workstation and run Restore Snapshot.
***  Exporting the settings doesn't include the default.cfg file


The following file needs to be manually copied from old computer to new.
* C:\ProgramData\Cardiff\TeleForm\Links\CapDir2\default.cfg


{{stub}}
If the whole problem is about file shares having been changed, then [[TISS28.accdb]] has some module contents that need to be changed as well.
[[Category: Data Processing]]
 
[[Category: TISS Scanning]]
=== Settings to make sure the pdf files make it to \\ad.wrha.mb.ca\WRHA\HSC\shared\MED\MED_CCMED\ ===
[[Category: IT Instructions]]
The location of the setting for where to store the output pdf is in '''Teleform Designer''',
[[Category: TISS]]
* File, open the form named TISS28 prod 2012-12-11
* menu form, autoexport setup
* make sure the "C:\.." setting is set to yes, and the "\\ad.wrha.mb.ca\WRHA\HSC\shared\MED\MED_CCMED\..." one to no. '''this is counter intuitive!''' For some reason the settings to store the image in x: are stored in the file stored on c:... These settings are linked to the main form itself (TISS28 prod 2012-12-11) so they need to be setup via opening the form.
 
* '''Most settings are located in TeleForm Designer via Utilities, Connect Agent Setup.'''
**this include network pathnames
 
=== Before considering the switch done ===
* confirm Pagasa can scan into TISS28.accdb, and without errors caused by update
* confirm that the .pdf files are stored on \\ad.wrha.mb.ca\WRHA\HSC\shared\MED\MED_CCMED\ on the path  that goes into the data imported into TISS.mdb
 
==Hardware==
=== [[Data Processor PC]] ===
see [[Data Processor PC]]
 
===Multifunction Printer/Scanner===
see [[Scanning to network]]
 
== Teleform Change Log==
===2019-07-06===
eHealth had made changes to network path names which affected scanning.  [[p:Herman Aubel]] fixed Path name in settings which are located in TeleForm Designer via Utilities, Connect Agent Setup. [[User:TOstryzniuk|Trish Ostryzniuk]] 11:56, 2019 July 15 (CDT)
 
[[Category:Teleform]]
[[Category:Legacy Data Processing]]
[[Category:Data Processor PC]]
}}

Latest revision as of 13:54, 2021 December 1

Legacy Content

This page contains Legacy Content.

Click Expand to show legacy content.

Teleform is a character recognition program used by the Data Processor to scan completed TISS forms before importing the data into the TISS28_Data.mdb. We use a network scanner for this.

Software

The Teleform suite consists of a number of separate programs or modules to support the designing and processing of data collection forms.

Version: 11x1_11117 as of 2016-06-02
Serial: 400796
License: TAH280-001H08-040001-H00WD7-D000RG-G77TZ6
Product License - {D73FC1DE-8D31-4DF7-B69B-80270B194BC4}

Not sure how those licenses are different, they came from an email from Florence Wong to Tina Tenbergen 2016-03-17.

File Locations

  • Export data (from Teleform): \\ad.wrha.mb.ca\WRHA\HSC\shared\MED\MED_CCMED\TISS28\ExportData
  • Scanned images: \\ad.wrha.mb.ca\WRHA\HSC\shared\MED\MED_CCMED\TISS28\ExportData\Images
  • no longer valid, our contract has expired - Service account login info: M:\Passwords_mainoffice\Passwords_MainOffice_use.xlsx

Sales and technical support

From: Digital Vision [1]
Sent: Wednesday, February 11, 2015 10:53
...
Pierce Ennessy
Digital Vision
TeleForm@att.net

US Toll Free: +1 844 526 7397

Updates

TeleForm has been completely transitioned to HP, Inc.
To learn more, including instructions for first time access, please refer to the User Guide.

Notes from Teleform install

changing path or similar in teleform

Teleform stores its config data in files all over the place. You can use TeleForm Maintenance and Utility to do a find-replace on them and update them, e.g. when eHealth changes file shares.

Copying settings from old to new PC

  • Export the current settings by opening TeleForm Maintenance and Utility.
    • Select Save snapshot
    • Select the categories you want to save
    • Click on the ... button to the right of Path and select the location to save the .zip file that contains the configuration files.
    • To restore the configuration, open TeleForm Maintenance and Utility on the new workstation and run Restore Snapshot.
      • Exporting the settings doesn't include the default.cfg file

The following file needs to be manually copied from old computer to new.

  • C:\ProgramData\Cardiff\TeleForm\Links\CapDir2\default.cfg

If the whole problem is about file shares having been changed, then TISS28.accdb has some module contents that need to be changed as well.

Settings to make sure the pdf files make it to \\ad.wrha.mb.ca\WRHA\HSC\shared\MED\MED_CCMED\

The location of the setting for where to store the output pdf is in Teleform Designer,

  • File, open the form named TISS28 prod 2012-12-11
  • menu form, autoexport setup
  • make sure the "C:\.." setting is set to yes, and the "\\ad.wrha.mb.ca\WRHA\HSC\shared\MED\MED_CCMED\..." one to no. this is counter intuitive! For some reason the settings to store the image in x: are stored in the file stored on c:... These settings are linked to the main form itself (TISS28 prod 2012-12-11) so they need to be setup via opening the form.
  • Most settings are located in TeleForm Designer via Utilities, Connect Agent Setup.
    • this include network pathnames

Before considering the switch done

  • confirm Pagasa can scan into TISS28.accdb, and without errors caused by update
  • confirm that the .pdf files are stored on \\ad.wrha.mb.ca\WRHA\HSC\shared\MED\MED_CCMED\ on the path that goes into the data imported into TISS.mdb

Hardware

Data Processor PC

see Data Processor PC

Multifunction Printer/Scanner

see Scanning to network

Teleform Change Log

2019-07-06

eHealth had made changes to network path names which affected scanning. p:Herman Aubel fixed Path name in settings which are located in TeleForm Designer via Utilities, Connect Agent Setup. Trish Ostryzniuk 11:56, 2019 July 15 (CDT)