HR: Difference between revisions

From CCMDB Wiki
Jump to navigation Jump to search
mNo edit summary
m Text replacement - "| element_description" to "| CCMDB_tab = Apache | element_description"
 
(20 intermediate revisions by 3 users not shown)
Line 1: Line 1:
The '''HR''' field is used to collect a patient's heart rate.
{{Data_element
| field_name = Ap_HeartRate
| CCMDB_label = Heart Rate
| CCMDB_tab = Apache
| element_description = The patient's {{#show: HR | ?AP phys name}} level in {{#show: HR | ?AP phys unit}}.
| in_table = L_Log table
| data_type = number
| datafield_length = single
| program_collecting = CC
| created_raw = Raw
| data_element_sort_index = 61
}}
== Different instructions for ICU and Medicine ==
The details of collection for ICU and medicine are different. For the timing and which value to use, see:
* for ICU: [[APACHE physiological variable collection]]
* for medicine: [[ALERT Scale timing of assessment]]


The unit used is beats per minute.
== Atrial Fibrillation ==
Select which ever value gives you the highest score.  When in atrial fibrillation, do not use this rate, use the ventricular rate.
When the patient is in atrial fibrillation, do not use the atrial rate use the ventricular rate.


Refer to [[General Collection Guidelines for Apache II#When to collect, which value to use]] for how and when to collect this.
{{APACHE physiological variable
|AP phys name=Heart Rate
|AP phys unit=beats/min
|AP phys absMax=205
|AP phys warnMax=250
|AP H4=>=180
|AP H3=>=140 and <180
|AP H2=>=110 and <140
|AP 0=>=70 and <110
|AP L2=>=55 and <70
|AP L3=>=40 and <55
|AP L4=<40
|AP phys warnMin=10
|AP phys absMin=5
}}


== {{CCMDB Data Integrity Checks}} ==
== Data Integrity Checks ==
* Must be (>=10 And <=250)
{{Data Integrity Check List}}


[[Category: APACHE II Physiological Variables]]
== Related articles ==
[[Category: MOST Score Elements]]
{{Related Articles}}
 
[[Category: ALERT Scale Elements]]

Latest revision as of 00:36, 2019 January 3

Data Element (edit)
Field Name: Ap_HeartRate
CCMDB Label: Heart Rate
CCMDB tab: Apache
Table: L_Log table
Data type: number
Length: single
Program: CC
Created/Raw: Raw
Start Date: 1988-07-11
End Date: 2300-01-01
Sort Index: 61

The patient's Heart Rate level in beats/min.

  • SMW

Legacy implementation right in the table

  • Cargo


  • Categories
  • Forms


Different instructions for ICU and Medicine

The details of collection for ICU and medicine are different. For the timing and which value to use, see:

Atrial Fibrillation

When the patient is in atrial fibrillation, do not use the atrial rate use the ventricular rate.


Apache Physiological Variable
variable name Heart Rate
unit beats/min
absolute max allowed 205
warning max 250
high score 4 >=180
high score 3 >=140 and <180
high score 2 >=110 and <140
high score 1
score 0 >=70 and <110
low score 1
low score 2 >=55 and <70
low score 3 >=40 and <55
low score 4 <40
AP phys warnMin 10
AP phys absMin 5

APACHE Score

This value is used to generate the APACHE Score.

Collecting Apache physiological variables

There are some specific rules to follow in choosing which one of several lab results to collect.

See APACHE physiological variable collection for details.

Cross Chcks

Rules described in APACHE_physiological_variable_collection#Exceptionally_high_or_low_values are implemented by Check APACHE physiological variable high low.

Data Integrity Checks

Data Integrity Checks (automatic list)

 AppStatus
Check APACHE physiological variable high lowCCMDB.accdbimplemented

Related articles

Related articles: