FiO2: Difference between revisions

From CCMDB Wiki
Jump to navigation Jump to search
TOstryzniuk (talk | contribs)
mNo edit summary
m Text replacement - "CCMDB.mdb" to "CCMDB.accdb"
 
(70 intermediate revisions by 6 users not shown)
Line 1: Line 1:
'''FiO<sub>2</sub>''' is the '''fraction of inspired oxygen''' in a gas mixture. [http://en.wikipedia.org/wiki/FiO2]
{{Data element
|field_name=Ap_FIO2
|CCMDB_label=FIO2
|Rank=Apache
|in_table=L Log table
|data_type=number
|datafield_length=single
|program_collecting=CC
|created_raw=Raw
|data_element_sort_index=67
|CCMDB_tab=Apache
|element_description=FIO2 is the '''fraction of inspired oxygen'''[http://en.wikipedia.org/wiki/FiO2] in the gas mixture breathed by the patient.
}}
It is an element of the [[Arterial blood gas (APACHE)]].


See http://en.wikipedia.org/wiki/FiO2


The FiO2's listed here are '''estimates only''' for the collection of arterial blood gas (ABG's) data for the [[APACHE Scoring table | APACHE II scoring]] purposes.  
== Collection Instructions ==
*The actual FiO2 that a patient gets varies due to a number of factors that are not accounted for in these estimates.
There are special collection instructions for [[Arterial blood gas (APACHE)]], refer there for further info. FIO2 collection is impacted by this.


{| class="wikitable" border=0
Enter the FiO2 by choosing the type and LPM in the drop-down in [[CCMDB.accdb]].
|- style="font-size:11pt"
| style="background-color:#8DB4E3" width="100" colspan="2" height="16" valign="bottom" | Nasal Prongs
| width="20"  valign="bottom" | &nbsp;
| style="background-color:#8DB4E3" width="97" colspan="2"  valign="bottom" | Partial Rebreath Mask
| width="20"  valign="bottom" | &nbsp;
| style="background-color:#8DB4E3" width="80" colspan="2"  valign="bottom" | Simple Flow Mask


|- style="font-size:11pt"  valign="bottom"
Once entered, your choice will translate into a number. If you go back to the dropdown later to check what you have entered, ''the type/LPM may not be what you entered'', but they will be something that corresponds to the same percentage FiO2. In other words, you can not go back to this field later to see the type or LPM you entered originally.
|style="background-color:#C5D9F1" height="15" width="80" | Room Air
|style="background-color:#C5D9F1" width="50" | 21%
| &nbsp;
|style="background-color:#C5D9F1" | 8 LRB
|style="background-color:#C5D9F1" | 65%
| &nbsp;
|style="background-color:#C5D9F1" width="80" | 6 Lpm
|style="background-color:#C5D9F1" width="50" | 35%


|- style="font-size:11pt"  valign="bottom"
|style="background-color:#C5D9F1" height="15" | 1 LNP
|style="background-color:#C5D9F1" | 24%
| &nbsp;
|style="background-color:#C5D9F1" | 10 LRB
|style="background-color:#C5D9F1" | 65%
| &nbsp;
|style="background-color:#C5D9F1" | 7 Lpm
|style="background-color:#C5D9F1" | 40%


|- style="font-size:11pt"  valign="bottom"
{{APACHE physiological variable
|style="background-color:#C5D9F1" height="15" | 2LNP
|AP phys name= fraction of inspired oxygen
|style="background-color:#C5D9F1" | 28%
|AP phys unit= percentage
| &nbsp;
|AP phys absMax= 100
|style="background-color:#C5D9F1" | 12 LRB
|AP phys warnMax= 100
|style="background-color:#C5D9F1" | 65%
|AP 0as per [[AaDO2]]
  | &nbsp;
|AP phys warnMin= 20
|style="background-color:#C5D9F1" | 8 Lpm
|AP phys absMin= 20
|style="background-color:#C5D9F1" | 45%
}}


|- style="font-size:11pt"  valign="bottom"
== FiO2 dropdown ==
|style="background-color:#C5D9F1" height="15" | 3 LNP
See drop-down in [[CCMDB.accdb]].
|style="background-color:#C5D9F1" | 32%
| &nbsp;
|style="background-color:#C5D9F1" | 13 LRB
|style="background-color:#C5D9F1" | 70%
| &nbsp;
|style="background-color:#C5D9F1" | 9 Lpm
|style="background-color:#C5D9F1" | 50%


|- style="font-size:11pt"  valign="bottom"
These FIO2's are '''estimates''' only that we use for the collection of arterial blood gas (ABG's) data for APACHE II scoring]] purposes. The actual FiO2 that a patient gets varies due to a number of factors that are not accounted for in these estimates. (breath rate and depth, distance of O2 diffuser from face, resistance to flow etc.)
|style="background-color:#C5D9F1" height="15" | 4 LNP
|style="background-color:#C5D9F1" | 36%
| &nbsp;
|style="background-color:#C5D9F1" | 15 LRB
|style="background-color:#C5D9F1" | 70%
| &nbsp;
|style="background-color:#C5D9F1" | 10 Lpm
|style="background-color:#C5D9F1" | 55%


|- style="font-size:11pt"  valign="bottom"
[https://bloggingforyournoggin.wordpress.com/2016/03/29/oxygen-flow-rate-and-fio2-understand-the-relationship/ Here is a link] for an article that deals with the relationship between FiO2 and flow rate.
|style="background-color:#C5D9F1" height="15" | 5 LNP
|style="background-color:#C5D9F1" | 40%
| &nbsp;
|style="background-color:#C5D9F1" | 15 LRB + 5 L NP
|style="background-color:#C5D9F1" | 70%
|| &nbsp;
|| &nbsp;
|| &nbsp;


|- style="font-size:11pt"  valign="bottom"
===OptiFlow===
|style="background-color:#C5D9F1" height="15" | 6 LNP
To get the FiO2 for optiflow
|style="background-color:#C5D9F1" | 44%
* if available, use the optiflow or "high flow" when initiated by respiratory.
| &nbsp;
* if that is not available, then as a default use the FIO2 you'd get with that oxygen flow with a regular nasal cannula
|style="background-color:#C5D9F1" | 10 LRB + 5 L NP
|style="background-color:#C5D9F1" | 70%
| &nbsp;
|style="background-color:#8DB4E3" colspan="2" | Cold Pot


|- style="font-size:11pt"  valign="bottom"
== Implementation ==
|style="background-color:#C5D9F1" height="15" | 7 LNP
The field draws its values from the [[S_FIO2 table]].
|style="background-color:#C5D9F1" | 48%
| &nbsp;
|style="background-color:#C5D9F1" | 10 LRB + 3 L NP
|style="background-color:#C5D9F1" | 70%
| &nbsp;
|style="background-color:#C5D9F1" | &nbsp;
|style="background-color:#C5D9F1" | 35%


|- style="font-size:11pt"  valign="bottom"
== Data Integrity Checks ==
|style="background-color:#C5D9F1" height="15" | 8 LNP
{{Data Integrity Check List}}
|style="background-color:#C5D9F1" | 50%
| &nbsp;
|style="background-color:#C5D9F1" | 15 LRB + 7 L NP
|style="background-color:#C5D9F1" | 70%
| &nbsp;
|style="background-color:#C5D9F1" | &nbsp;
|style="background-color:#C5D9F1" | 40%


|- style="font-size:11pt"  valign="bottom"
== Related articles ==
| height="15" | &nbsp;
{{Related Articles}}
|
| &nbsp;
| &nbsp;
| &nbsp;
| &nbsp;
|style="background-color:#C5D9F1" | &nbsp;
|style="background-color:#C5D9F1" | 50%


|- style="font-size:11pt"
[[Category: ABG]]
|style="background-color:#8DB4E3" colspan="2" height="15" valign="bottom" | Non Rebreath Mask
[[Category: Standards and Conventions]]
|  valign="bottom" | &nbsp;
|style="background-color:#8DB4E3" colspan="2" valign="bottom" | Venturi Face Mask
|  valign="bottom" | &nbsp;
|style="background-color:#C5D9F1"  valign="bottom" | &nbsp;
|style="background-color:#C5D9F1"  valign="bottom" | 70%
 
|- style="font-size:11pt"  valign="bottom"
|style="background-color:#C5D9F1" height="15" | 10 LNRB
|style="background-color:#C5D9F1" | 70%
| &nbsp;
|style="background-color:#C5D9F1" | 3 Lpm
|style="background-color:#C5D9F1" | 24%
| &nbsp;
|style="background-color:#C5D9F1" | &nbsp;
|style="background-color:#C5D9F1" | 100%
 
|- style="font-size:11pt"  valign="bottom"
|style="background-color:#C5D9F1" height="15" | 15 LNRB
|style="background-color:#C5D9F1" | 70%
| &nbsp;
|style="background-color:#C5D9F1" | 4 Lpm
|style="background-color:#C5D9F1" | 26%
| &nbsp;
| &nbsp;
| &nbsp;
 
|- style="font-size:11pt"  valign="bottom"
|style="background-color:#C5D9F1" height="15" | 20 LNRB
|style="background-color:#C5D9F1" | 80%
| &nbsp;
|style="background-color:#C5D9F1" | 5 Lpm
|style="background-color:#C5D9F1" | 28%
| &nbsp;
|style="background-color:#8DB4E3" colspan="2" | BiPAP
 
|- style="font-size:11pt"  valign="bottom"
|style="background-color:#C5D9F1" height="15" | 25 LNRB
|style="background-color:#C5D9F1" | 80%
| &nbsp;
|style="background-color:#C5D9F1" | 6 Lpm
|style="background-color:#C5D9F1" | 30%
| &nbsp;
|style="background-color:#C5D9F1" | 5 L
|style="background-color:#C5D9F1" | 40%
 
|- style="font-size:11pt"  valign="bottom"
|style="background-color:#C5D9F1" height="15" | 30 LNRB
|style="background-color:#C5D9F1" | 80%
| &nbsp;
|style="background-color:#C5D9F1" | 9 Lpm
|style="background-color:#C5D9F1" | 35%
| &nbsp;
|style="background-color:#C5D9F1" | 10 L
|style="background-color:#C5D9F1" | 60%
 
|- style="font-size:11pt"  valign="bottom"
|style="background-color:#C5D9F1" height="15" | 100 LNRB
|style="background-color:#C5D9F1" | 80%
| &nbsp;
|style="background-color:#C5D9F1" | 12 Lpm
|style="background-color:#C5D9F1" | 40%
| &nbsp;
|style="background-color:#C5D9F1" | 15 L
|style="background-color:#C5D9F1" | 70%
 
|- style="font-size:11pt"  valign="bottom"
| height="15" | &nbsp;
| &nbsp;
| &nbsp;
|style="background-color:#C5D9F1" | 15 Lpm
|style="background-color:#C5D9F1" | 50%
| &nbsp;
|style="background-color:#C5D9F1" | Flush
|style="background-color:#C5D9F1" | 70%
 
|}
 
== Relevance ==
The FiO2 is used to calculate the AaDO2 which is a component of the APACHE score as follows:
for FiO<sub>2</sub> >= 50 %,
AaDO<sub>2</sub> = ((FiO<sub>2</sub> * 713) - [[PO2]]) - [[Serum CO2]]
 
 
 
[[Category:Data_Collection_Guide]]
[[Category:APACHE II]]

Latest revision as of 10:43, 2019 September 22

Data Element (edit)
Field Name: Ap_FIO2
CCMDB Label: FIO2
CCMDB tab: Apache
Table: L Log table
Data type: number
Length: single
Program: CC
Created/Raw: Raw
Start Date: 1988-07-11
End Date: 2300-01-01
Sort Index: 67

FIO2 is the fraction of inspired oxygen[1] in the gas mixture breathed by the patient.

  • SMW

Legacy implementation right in the table

  • Cargo


  • Categories
  • Forms


It is an element of the Arterial blood gas (APACHE).

See http://en.wikipedia.org/wiki/FiO2

Collection Instructions

There are special collection instructions for Arterial blood gas (APACHE), refer there for further info. FIO2 collection is impacted by this.

Enter the FiO2 by choosing the type and LPM in the drop-down in CCMDB.accdb.

Once entered, your choice will translate into a number. If you go back to the dropdown later to check what you have entered, the type/LPM may not be what you entered, but they will be something that corresponds to the same percentage FiO2. In other words, you can not go back to this field later to see the type or LPM you entered originally.


Apache Physiological Variable
variable name fraction of inspired oxygen
unit percentage
absolute max allowed 100
warning max 100
high score 4
high score 3
high score 2
high score 1
score 0 as per AaDO2
low score 1
low score 2
low score 3
low score 4
AP phys warnMin 20
AP phys absMin 20

APACHE Score

This value is used to generate the APACHE Score.

Collecting Apache physiological variables

There are some specific rules to follow in choosing which one of several lab results to collect.

See APACHE physiological variable collection for details.

Cross Chcks

Rules described in APACHE_physiological_variable_collection#Exceptionally_high_or_low_values are implemented by Check APACHE physiological variable high low.

FiO2 dropdown

See drop-down in CCMDB.accdb.

These FIO2's are estimates only that we use for the collection of arterial blood gas (ABG's) data for APACHE II scoring]] purposes. The actual FiO2 that a patient gets varies due to a number of factors that are not accounted for in these estimates. (breath rate and depth, distance of O2 diffuser from face, resistance to flow etc.)

Here is a link for an article that deals with the relationship between FiO2 and flow rate.

OptiFlow

To get the FiO2 for optiflow

  • if available, use the optiflow or "high flow" when initiated by respiratory.
  • if that is not available, then as a default use the FIO2 you'd get with that oxygen flow with a regular nasal cannula

Implementation

The field draws its values from the S_FIO2 table.

Data Integrity Checks

Data Integrity Checks (automatic list)

 AppStatus
Check APACHE physiological variable high lowCCMDB.accdbimplemented

Related articles

Related articles: