TISS28 Form Scanning: Difference between revisions

From CCMDB Wiki
Jump to navigation Jump to search
mNo edit summary
 
(309 intermediate revisions by 4 users not shown)
Line 1: Line 1:
The purpose of this article is to outline the process of scanning TISS28 paper forms, verifying the data in Teleform and committing the data to the TISS28 MS Access database.
Legacy process 2020-Dec-7  (a few forms still coming and scanned Feb 2021 in from Dec 2020 backlog)
The purpose of this article is to outline the process of scanning TISS28 paper forms, verifying the data in Teleform and committing the data to the [[TISS28_Data.mdb | TISS28 MS Access database]].


These instructions are applicable to the following:
These instructions are applicable to the following:
Line 7: Line 8:
For additional information see this article:  [[Teleform]]
For additional information see this article:  [[Teleform]]


== Preparation ==
=== Get files to PC ===
*a. Follow the process in [["Copying" Centralized data.mdb]] to copy files used by this process into the [[Frozen]] folder on the [[Data Processor]]s desktop
*b. Open [[TISS28.accdb]] (use shortcut on processors desktop)
**click the "'''Reconnect .MDBs'''" button <!-- this is NOT [[Reconnect CFE and initial error checks]], the cross checks involved with that don't apply here. -->


Steps required to Navigating through Teleform Programs.
=== Teleform scan station prep ===
On scanner PC:
*a. Double-click on the '''Teleform Reader''' shortcut on the desktop (eyeglasses icon)
*b. double click to open '''Teleform Verifier'''


=== Scanning forms ===
'''Ready to scan forms'''
On the scanner:
# put forms into scanner
# on scanner interface, click '''"Scan to Network"'''
# click "Scan to Network" a '''second time'''
# click '''"change..."'''  
#* {{discussion}} we should ask the printing people if they can make this the default;
#** I have emailed the helpdesk about this Ttenbergen 16:08, 2015 March 26 (CDT)
#* under "sides(duplex)" choose "2 sided"
#* under "Scan As" choose TIFF
# click "Scan it" button


=== Teleform ScanStation ===
=== forms ===
On the Scanner PC:
''' There used to be preparation of forms, but there no longer is.''' I.e leave the page numbers alone, or use 001.
# Double-click on the '''Teleform ScanStation''' shortcut on the desktop
# Select '''File''', '''New Batch'''
# Click '''Start''' buttom in bottom left
# Click '''Accept'''
* leave Teleform Scan Station open


=== Verifying ===
== Scanning forms ==
# Double-click on the '''Teleform Verifier''' shortcut on the desktop
For general scanning instructions including for TISS28, see [[Scanning_to_network#Instructions]].
# click on the line with the latest batch number, status column should say "Ready for Correction"
# click the "Process" button on the right
# click the "AB12" button in the button bar to change view to form view
# correct all entries the program presents
# when dialog box asks "save corrections to results file" click OK
# right-click the batch and click "Commit"; say "OK" to "Commit batch data?"


==Filing of TISS28 forms==
''We have had repeated problems with the scanner, see [[Main office scanning problems]].''
Being stored as electronic and paper form.


===Electronic Images===
== Verifying ==
The scanned images are stored on the following network share:
=== Correcting forms ===
*\\hsc1msfp0001\med_ccmed\TISS28\ExportData\Images
* wait for the last line to say "ready for correction" (starts as "evaluating") <!-- it always gets to this "OK" -->
This share has a sub-folder for each batch that has been processed.  Currently there are two types of batch numbers.  Any folder in this directory with the suffix:  "_old" is pre-Windows7. The Windows 7 upgrade involved upgrading Teleform.  The Teleform upgrade caused a reset to the sequence of batch numbers.  All code in the TISS28 DB has been updated and is fully operational for this change.  All batches going forward are simply numeric.
* last line may be highlighted; double click on the last line
* will show error , how to correct
* can see error where highlited blue
* check each line that is "xed" out. click on the data point in the form and enter the correct value below
* click OK when asked "Saved corrections to results file?"
* when you are done correcting all lines, the program returns you to the Teleform Verifier


===Locating Images===
=== Finishing off / Committing a batch ===
There are two methods that can be used to locate an image.  Simply by serial number - this is the serial number entered on the form at the hospital.  There are duplicate serial numbers and this method will return all potential matches but will show the following information:
* check if column Scan column and eval column have the same number in them
*Site
** '''only if different''', right-click line, discard, and start that batch over.
*Unit
* Right-click the batch and click "Commit"; say "Yes".
*Serial
*Batch No
*First Date
*Image File - with the option to open and view the file (click the button next to this field on the form)


An alternate method is to search based on a combination of: Site + Unit + Serial
Info only:  
* When you click commit the batch sits in [[X:\]]TISS28\ExportData
* See [[TISS28 form images]] for how these images are dealt with after processing


This method reports the same data outlined above.
==Importing batch into [[TISS28.accdb]]==
# if you have not done so before you started toscan started, open the '''[[TISS28.accdb]]''' (Access icon), Enter password  (a list of main office passwords are stored in an Excel file on "M")
# click "Re-connect.MDBs" button one time only at the beginning
# Click "Import TISS Data", click "OK" for success message (takes <1 minute)
#* when done, program says "Successfully imported data from <THE NUMBER> TISS forms." (this number is pretty much never wrong)
#* There might be an error titled "Form already exists" with content "a scanned form has a D_ID and first date that already exists in L_TISS Form.  Click OK to see query. You might be able to edit the TISS_export table to resolve the issue(e.g. delete the offending line).  Click OK to re-check or cancel and stop import."; if so see [[Deleting a duplicate record from the TISS pre-import file]]
# A table will show up - "qryConfirmImport"
# Verify that you have a line with correct D_ID for each form
# Close the '''[[TISS28.accdb]]''' when you have completed all the forms


===Backups of the Forms===
===Scan batch number recording & temporary form stacking===
The forms are backed up from the scanner PC to [[X:\]]TISS28\ExportData\Images
* After you import a group of TISS forms,  put the batch number only on the first form then stack it on top of the left-most pile, rotating it 90 degrees from the previous batch
** make a new pile if the pile gets too high, >~2in


====Disposing of the TISS forms====
* We keep about 3 months / 3 stacks of TISS forms
* [[Confidential waste disposal#HSC]] the oldest (right-most) pile when ready


=Supplementary Information=
== Error checking ==
===Scan and TOSS - target date ===
The [[Data processor]] usually scans all forms that are currently waiting for scanning before processing the error checking queries because it is faster that way. However, this may require keeping track of progress between scanning sessions, so for anyone covering it might be better to process the queries before the end of each shift.  
'''May 1.2015'''
*We are at the point the we can scan then tossing out TISS forms immediately after scanning.  The image being stored is adequate and accessible by processor (need steps documented). This would reduce data processor workload in regards to filing, clipping together and adding stickies with scan batch number.  Tina to do final review with Pagasa and advise if May 1.15 is a go to '''scan and TOSS'''. Pagasa to raise this with Tina so she can review any process details if needed before the scan and TOSS date. [[User:TOstryzniuk|Trish Ostryzniuk]] 18:32, 2015 March 13 (CDT)


==Other things to resolve with data processing==
See [[TISS28 Data Integrity Checks]] for a list of the scans and how to deal with them...
*site STB ICMS & STB ICCS - will want a PROGRAM & not a data collector to correct the location name on form for STB
*if STB_ICMS convert to STB_MICU
*if STB_ICCS convert to STB_CICU


Is this an outstanding problem? If so, please add to [[Change Priorities]]. Ttenbergen 19:32, 2014 April 30 (CDT)[[User:TOstryzniuk|Trish Ostryzniuk]] 18:33, 2015 March 13 (CDT){{Potential Change}}
When all forms/batches for "this round" have been scanned (possibly less often, we'll catch in the end), run each of the TISS_Error_* queries. 


==Trouble shooting of the tiss 28 forms==
* In the following, if there is data for an extra TISS day that is identical to previous, just delete it; if the "offending" TISS day is different from surrounding, then confirm with collector
*If encountered problem like this message "the instruction at 0X3894ffo"
* If query is empty, run next; else:
*Go to X:\Tiss28
<!-- see [[Template:Data Integrity Check]] for how to get things on this list. -->
*Then open the ExportData with 2 folders 1) Images 2)Archives.
{{#ask: [[DICApp::TISS28.accdb]]
*Archive is the csv data of the batch you scanned and verified after you commited the batch in the Teleform it goes to the Archive folder.
|?DICStatus = Status
*Sometimes the error messages shows up when commitng so I dont import the batch and check what is the problem.
|?Modification date
*Some of the common error are if the Location or the Site is incorrect it just give you this error message"the instruction at 0X3894ffo
|limit=10000
*Go To Access database into the Edit Tiss data click find and enter the serial number.
|format=broadtable
|link=all
  |class=sortable wikitable smwtable
  |default= '''No {{PAGENAME}} found'''
}}


== Original transition from TISS76 to TISS28 ==
==== Why are these checks not done in CFE where the data would be easy to edit?  ====
*Example: If patient has one page already completed in December and a NEW TISS form is started Jan 1, is this page number 2?
The reason the checks are done in TISS rather than CFE, even though a frozen version of CFE is used to look up and email, is to reduce push-pull cycles. Could not pull current version of CFE to make changes because TISS Scanning is always done while collectors are [[Sending Patients]].
** as addressed in email over holidays, doesn't matter what number is used since the field is not imported. Ttenbergen 11:10, 2013 January 7 (EST)
*Cannot scan tiss if CFE is in pull. I do scanning when CFE is in push and do the checking at the same time.


January 1, 2013 - New TISS28 forms; we will scan all pages for entire patients LOS in ICU. New form will have 7 days per form. TISS28 data will NOT be uploaded to master TMSX (Critical Care) database.  See [[TISS28_data_specifications#Location_of_data]] about where thsi will be stored.
== background info ==


[[Category: Teleform]]
===Start Date===
[[Category: Data Processing]]
'''2013-Jan-01'''
[[Category: TISS Scanning]]
*TISS28 data for the '''entire LOS''' is scanned and stored in new repository [[TISS28_Data.mdb]]. This form has 7 days per page.
[[Category: TISS28]]
===Stop Date===
'''2020-Dec-7''' 
*See: [[Change to collect TISS data in CCI Picklist]]
 
== Related articles ==
{{Related Articles}}
 
[[Category:Legacy Data Processing]]
[[Category:TISS28 Scanning Process | *]]
[[Category:Teleform]]
[[Category:Data Processing]]
[[Category:TISS Scanning]]
[[Category:TISS28.accdb]]

Latest revision as of 11:26, 2022 July 28

Legacy process 2020-Dec-7  (a few forms still coming and scanned Feb 2021 in from Dec 2020 backlog)

The purpose of this article is to outline the process of scanning TISS28 paper forms, verifying the data in Teleform and committing the data to the TISS28 MS Access database.

These instructions are applicable to the following:

  • Teleform version 10.9 installed in a PC running Windows 7
  • Scanning to a network share from a multifunction printer/scanner

For additional information see this article: Teleform

Preparation

Get files to PC

Teleform scan station prep

On scanner PC:

  • a. Double-click on the Teleform Reader shortcut on the desktop (eyeglasses icon)
  • b. double click to open Teleform Verifier

Ready to scan forms

forms

There used to be preparation of forms, but there no longer is. I.e leave the page numbers alone, or use 001.

Scanning forms

For general scanning instructions including for TISS28, see Scanning_to_network#Instructions.

We have had repeated problems with the scanner, see Main office scanning problems.

Verifying

Correcting forms

  • wait for the last line to say "ready for correction" (starts as "evaluating")
  • last line may be highlighted; double click on the last line
  • will show error , how to correct
  • can see error where highlited blue
  • check each line that is "xed" out. click on the data point in the form and enter the correct value below
  • click OK when asked "Saved corrections to results file?"
  • when you are done correcting all lines, the program returns you to the Teleform Verifier

Finishing off / Committing a batch

  • check if column Scan column and eval column have the same number in them
    • only if different, right-click line, discard, and start that batch over.
  • Right-click the batch and click "Commit"; say "Yes".

Info only:

  • When you click commit the batch sits in X:\TISS28\ExportData
  • See TISS28 form images for how these images are dealt with after processing

Importing batch into TISS28.accdb

  1. if you have not done so before you started toscan started, open the TISS28.accdb (Access icon), Enter password (a list of main office passwords are stored in an Excel file on "M")
  2. click "Re-connect.MDBs" button one time only at the beginning
  3. Click "Import TISS Data", click "OK" for success message (takes <1 minute)
    • when done, program says "Successfully imported data from <THE NUMBER> TISS forms." (this number is pretty much never wrong)
    • There might be an error titled "Form already exists" with content "a scanned form has a D_ID and first date that already exists in L_TISS Form. Click OK to see query. You might be able to edit the TISS_export table to resolve the issue(e.g. delete the offending line). Click OK to re-check or cancel and stop import."; if so see Deleting a duplicate record from the TISS pre-import file
  4. A table will show up - "qryConfirmImport"
  5. Verify that you have a line with correct D_ID for each form
  6. Close the TISS28.accdb when you have completed all the forms

Scan batch number recording & temporary form stacking

  • After you import a group of TISS forms, put the batch number only on the first form then stack it on top of the left-most pile, rotating it 90 degrees from the previous batch
    • make a new pile if the pile gets too high, >~2in

Disposing of the TISS forms

Error checking

The Data processor usually scans all forms that are currently waiting for scanning before processing the error checking queries because it is faster that way. However, this may require keeping track of progress between scanning sessions, so for anyone covering it might be better to process the queries before the end of each shift.

See TISS28 Data Integrity Checks for a list of the scans and how to deal with them...

When all forms/batches for "this round" have been scanned (possibly less often, we'll catch in the end), run each of the TISS_Error_* queries.

  • In the following, if there is data for an extra TISS day that is identical to previous, just delete it; if the "offending" TISS day is different from surrounding, then confirm with collector
  • If query is empty, run next; else:
 StatusModification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by Semantic MediaWiki.
Query TISS Errors BIPAP vs BIPAP2300retired8 September 2021 16:33:10
Query TISS Errors CVC vs CVC2300retired8 September 2021 16:33:12
Query TISS Errors D ID not in CFEretired8 September 2021 16:33:04
Query TISS Errors TISS date out of admissionretired19 April 2022 20:28:53
Query TISS Errors duplicate Itemsretired7 October 2021 20:14:46
Query TISS Errors missing daysretired19 April 2022 20:47:33

Why are these checks not done in CFE where the data would be easy to edit?

The reason the checks are done in TISS rather than CFE, even though a frozen version of CFE is used to look up and email, is to reduce push-pull cycles. Could not pull current version of CFE to make changes because TISS Scanning is always done while collectors are Sending Patients.

  • Cannot scan tiss if CFE is in pull. I do scanning when CFE is in push and do the checking at the same time.

background info

Start Date

2013-Jan-01

  • TISS28 data for the entire LOS is scanned and stored in new repository TISS28_Data.mdb. This form has 7 days per page.

Stop Date

2020-Dec-7

Related articles

Related articles: